This document describes the types of third-party devices that EcoStruxure IT Expert
can monitor. Inclusion in this report does not guarantee a specific device can be
monitored. For information about new releases, see the
EcoStruxure IT Gateway device library release notes in the EcoStruxure IT Help Center.
Supported Third-Party Devices
Device library v3.1.0.4
October 2025
2BM 2BM RPDU RPDU
| Manufacturer: |
2BM |
| Device Type: |
2BM RPDU |
| Family: |
RPDU |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
ABB Branch Circuit Monitor CMS600
| Manufacturer: |
ABB |
| Device Type: |
Branch Circuit Monitor |
| Family: |
CMS600 |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
| This DDF was created using DCE DDF abb_cms600.xml version 3 |
Reference Documents:
| Document: |
abb_cms600.xml |
| Version: |
3 |
| Sections: |
Not Available
|
| URL: |
Not Available
|
AKCP EMS Sensor Probe Plus
| Manufacturer: |
AKCP |
| Device Type: |
EMS |
| Family: |
Sensor Probe Plus |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
akcp (07_06_2017).mib |
| Version: |
Not Available
|
| Sections: |
plusSeries (.1.3.6.1.4.1.3854.3)
temperatureTable (.1.3.6.1.4.1.3854.3.5.2)
humidityTable (.1.3.6.1.4.1.3854.3.5.3)
drycontactTable (.1.3.6.1.4.1.3854.3.5.4)
sirenTable (.1.3.6.1.4.1.3854.3.5.11)
relayTable (.1.3.6.1.4.1.3854.3.5.12)
|
| URL: |
Not Available
|
AKCP EMS Sensor Probe
| Manufacturer: |
AKCP |
| Device Type: |
EMS |
| Family: |
Sensor Probe |
| Protocol: |
SNMP |
Models Tested:
| Sensor Probe 2 |
| Sensor Probe 8 |
Network Cards:
Additional Information:
Reference Documents:
| Document: |
akcp (07_06_2017).mib |
| Version: |
Not Available
|
| Sections: |
sensorProbe (.1.3.6.1.4.1.3854.1)
sensorProbeTempTable (.1.3.6.1.4.1.3854.1.2.2.1.16)
sensorProbeHumidityTable (.1.3.6.1.4.1.3854.1.2.2.1.17)
sensorProbeSwitchTable (.1.3.6.1.4.1.3854.1.2.2.1.18)
sensorProbeDrycontactArraySensor (.1.3.6.1.4.1.3854.1.2.2.1.19.37)
|
| URL: |
Not Available
|
AMI Server Redfish Server
| Manufacturer: |
AMI |
| Device Type: |
Server |
| Family: |
Redfish Server |
| Protocol: |
REDFISH |
Models Tested:
Network Cards:
| ASUS ASMB9-iKVM Server Management Board |
Additional Information:
Reference Documents:
ASCO ATS 72EE
| Manufacturer: |
ASCO |
| Device Type: |
ATS |
| Family: |
72EE |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| 72EE |
| Firmware Versions: |
| 607540-056 |
| 894063-014 |
| 894063-015 |
Additional Information:
| A small subset of possible sensors are available at this time. |
Reference Documents:
ASCO Power Technologies (by Schneider Electric) Power Meter G5 Group Controller
| Manufacturer: |
ASCO Power Technologies (by Schneider Electric) |
| Device Type: |
Power Meter |
| Family: |
G5 Group Controller |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Connectivity to the ASCO(R) Power Manager Xp & 7000 Series Group 5 Controller via
Modbus(R) |
| Version: |
381339-221I |
| Sections: |
Register Map for Group 5 Controller(pgs.18-19) |
| URL: |
Not Available
|
| Document: |
Connectivity to the ASCO(R) Power Manager Xp & 7000 Series Group 5 Controller via
Modbus(R) |
| Version: |
381339-221Q, 02/2023 |
| Sections: |
Register Map for Group 5 Controller(pgs.19-23) |
| URL: |
Not Available
|
ASCO Power Technologies (by Schneider Electric) Power Meter Power Manager Xp 7000 Series
| Manufacturer: |
ASCO Power Technologies (by Schneider Electric) |
| Device Type: |
Power Meter |
| Family: |
Power Manager Xp 7000 Series |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Connectivity to the ASCO(R) Power Manager Xp & 7000 Series Group 5 Controller via
Modbus(R) |
| Version: |
381339-221I |
| Sections: |
Register Map for Power Manager Xp(pgs.12-17) |
| URL: |
Not Available
|
AVTech EMS RoomAlert 3S
| Manufacturer: |
AVTech |
| Device Type: |
EMS |
| Family: |
RoomAlert 3S |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
Additional Information:
Reference Documents:
| Document: |
ROOMALERT3S.MIB |
| Version: |
1.3.1 |
| Sections: |
internal (.1.3.6.1.4.1.20916.1.13.1.1.x), digital (.1.3.6.1.4.1.20916.1.13.1.2.x),
switch (.1.3.6.1.4.1.20916.1.13.1.3.x) |
| URL: |
Not Available
|
Advance Cooling Systems (ACS) CRAC ACS_CRAC
| Manufacturer: |
Advance Cooling Systems (ACS) |
| Device Type: |
CRAC |
| Family: |
ACS_CRAC |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Panel AC Modbus Communication |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
| Document: |
Panel AC Communication |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
Airedale CRAC EasiCool EZRE Precision Air Conditioning
| Manufacturer: |
Airedale |
| Device Type: |
CRAC |
| Family: |
EasiCool EZRE Precision Air Conditioning |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
MIB Browser-Export---10.3.16.122---DETAILED.csv |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
Airedale International CRAC SmartCool Precision Air Conditioner
| Manufacturer: |
Airedale International |
| Device Type: |
CRAC |
| Family: |
SmartCool Precision Air Conditioner |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
SmartCool BMS Points |
| Version: |
V6.00 |
| Sections: |
Analogue Variables (pgs.1-2), Integer Variables (pgs.2-4), Digital Variables(pgs.4-7) |
| URL: |
Not Available
|
Alcatel Switch
| Manufacturer: |
Alcatel |
| Device Type: |
Switch |
| Family: |
Not Available
|
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Alltec EMS Leak Detector
| Manufacturer: |
Alltec |
| Device Type: |
EMS |
| Family: |
Leak Detector |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Alpha System Level Controller Cordex-CXC
| Manufacturer: |
Alpha |
| Device Type: |
System Level Controller |
| Family: |
Cordex-CXC |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Alpha Technologies UPS Alpha FXM
| Manufacturer: |
Alpha Technologies |
| Device Type: |
UPS |
| Family: |
Alpha FXM |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| CXC RMU |
| Firmware Versions: |
| 2.01.00 |
| 2.06.00 |
Additional Information:
Reference Documents:
| Document: |
Argus-Power-System-MIB.mib |
| Version: |
201612090000Z - December 9, 2016 |
| Sections: |
1.3.6.1.4.1.7309.6.1.* |
| URL: |
Not Available
|
Arctic Chiller Group Chiller Manhattan Modular
| Manufacturer: |
Arctic Chiller Group |
| Device Type: |
Chiller |
| Family: |
Manhattan Modular |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Manhattan Points List |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
Arctic Chiller Group Pump Manhattan Modular
| Manufacturer: |
Arctic Chiller Group |
| Device Type: |
Pump |
| Family: |
Manhattan Modular |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
20100507091536 |
| Version: |
Not Available
|
| Sections: |
Pump Module Parameters Table(pg.6) |
| URL: |
Not Available
|
BachMann RPDU Blue Net
| Manufacturer: |
BachMann |
| Device Type: |
RPDU |
| Family: |
Blue Net |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Bard CRAC 7960-791G
| Manufacturer: |
Bard |
| Device Type: |
CRAC |
| Family: |
7960-791G |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Basler Electric Generator DGC-2020 Digital Genset Controller
| Manufacturer: |
Basler Electric |
| Device Type: |
Generator |
| Family: |
DGC-2020 Digital Genset Controller |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Instruction Manual For Digital Genset Controller DGC-2020 |
| Version: |
Revision R, October 2011 |
| Sections: |
Legacy Parameter Table(pgs.B72-B85) |
| URL: |
Not Available
|
Basler Electric Generator DGC-2020 Digital Genset Controller
| Manufacturer: |
Basler Electric |
| Device Type: |
Generator |
| Family: |
DGC-2020 Digital Genset Controller |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Instruction Manual For Digital Genset Controller DGC-2020 |
| Version: |
Revision R, October 2011 |
| Sections: |
Current Parameter Table(pgs.B8-B71) |
| URL: |
Not Available
|
Baytech RPDU MRP-series
| Manufacturer: |
Baytech |
| Device Type: |
RPDU |
| Family: |
MRP-series |
| Protocol: |
SNMP |
Models Tested:
| R24 MRP-11396A1 |
| R33 MRP-143DB71 |
Network Cards:
| DS72 |
| Firmware Versions: |
| 2.23.09 |
Additional Information:
Reference Documents:
| Document: |
bayuniv-4014.mib |
| Version: |
4.01.4 |
| Sections: |
sBTAModulesRPCTable (.1.3.6.1.4.1.4779.1.3.5.2)
sBTAModulesRPCOutletTable (.1.3.6.1.4.1.4779.1.3.5.3)
sRPCModPortCircuitsTable (.1.3.6.1.4.1.4779.1.3.5.10)
sBTAModulesEnvironmentalObjectsTable (.1.3.6.1.4.1.4779.1.6.1)
|
| URL: |
https://www.baytech.net/docs-and-downloads/
|
Black Box EMS ServSensor
| Manufacturer: |
Black Box |
| Device Type: |
EMS |
| Family: |
ServSensor |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
blackbox.mib |
| Version: |
Not Available
|
| Sections: |
servSensor (.1.3.6.1.4.1.3854.1)
servSensorTempTable (.1.3.6.1.4.1.3854.1.2.2.1.16)
servSensorHumidityTable (.1.3.6.1.4.1.3854.1.2.2.1.17)
servSensorSwitchTable (.1.3.6.1.4.1.3854.1.2.2.1.18)
servSensorDrycontactArraySensor (.1.3.6.1.4.1.3854.1.2.2.1.19.37)
|
| URL: |
Not Available
|
Carel CRAC IR33
| Manufacturer: |
Carel |
| Device Type: |
CRAC |
| Family: |
IR33 |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Carrier Global Corporation Chiller AquaSnap
| Manufacturer: |
Carrier Global Corporation |
| Device Type: |
Chiller |
| Family: |
AquaSnap |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
| This DDF is created based on the DCE DDF Version 4 carrier_aquasnap30rap030.xml |
Reference Documents:
Carrier Global Corporation CRAC AquaSnap Chiller
| Manufacturer: |
Carrier Global Corporation |
| Device Type: |
CRAC |
| Family: |
AquaSnap Chiller |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Default JBus Memory Mapping for LEI Gateway |
| Version: |
Rev. C, 08/29/2007 |
| Sections: |
JBus Memory Mapping - 30RB & 30RQ Default Configuration(pgs.10-11) |
| URL: |
Not Available
|
Caterpillar Inc. Generator Electronic Modular Control Panel (EMCP) 3.x
| Manufacturer: |
Caterpillar Inc. |
| Device Type: |
Generator |
| Family: |
Electronic Modular Control Panel (EMCP) 3.x |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
APPLICATION AND INSTALLATION GUIDE, EMCP 3.1, 3.2, 3.3 GENERATOR SET CONTROL (LEBE5255) |
| Version: |
November 2005 |
| Sections: |
Appendix F - Quick Reference Chart of Modbus Registers (pgs.147-161) |
| URL: |
Not Available
|
| Document: |
EMCP3MODBUSext21Prod2007-05-22-v2_Compare_DDF.xls |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
Caterpillar Inc. Generator Electronic Modular Control Panel (EMCP) 4.x
| Manufacturer: |
Caterpillar Inc. |
| Device Type: |
Generator |
| Family: |
Electronic Modular Control Panel (EMCP) 4.x |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
APPLICATION AND INSTALLATION GUIDE EMCP4 |
| Version: |
Not Available
|
| Sections: |
Appendix A - Modbus Register Data (pgs.49-63) |
| URL: |
Not Available
|
| Document: |
EMCP Modbus Register List Version 1[ECMP4].pdf |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
Chatsworth RPDU
| Manufacturer: |
Chatsworth |
| Device Type: |
RPDU |
| Family: |
Not Available
|
| Protocol: |
SNMP |
Models Tested:
| P3-1H0E3-B2A |
| P6-1F0A1-C2A |
| P4-1P0F3-C3E |
| P5-2R0C3-C7H |
Network Cards:
| eConnect |
| Firmware Versions: |
| 1.17.232 |
| 1.23.146 |
| 2.22.216 |
| 2.23.126 |
Additional Information:
Reference Documents:
Chloride / Liebert / Vertiv UPS Liebert NX/SX - Chloride ManageUPS Net Adapter
| Manufacturer: |
Chloride / Liebert / Vertiv |
| Device Type: |
UPS |
| Family: |
Liebert NX/SX - Chloride ManageUPS Net Adapter |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
| Chloride ManageUPS Net Adapter |
Additional Information:
Reference Documents:
| Document: |
Liebert IntelliSlot Modbus 485, Modbus IP and BACnet IP, Reference Guide |
| Version: |
Not Available
|
| Sections: |
3.3 UPS Systems - Table 58 - Liebert NX 225-600kVA UPS - Input and Holding |
| URL: |
Not Available
|
| Document: |
Chloride ManageUPS (80Net) |
| Version: |
Not Available
|
| Sections: |
Table 3.88 NX 225-600kVA UPS—Chloride ManageUPS—Input and Holding |
| URL: |
Not Available
|
Circutor Power Meter CVM-NRG96
| Manufacturer: |
Circutor |
| Device Type: |
Power Meter |
| Family: |
CVM-NRG96 |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Cisco Switch Catalyst
| Manufacturer: |
Cisco |
| Device Type: |
Switch |
| Family: |
Catalyst |
| Protocol: |
SNMP |
Models Tested:
| WS-C2960G-24TC-L |
| WS-C3560G-48TS-E |
| WS-C4500X-32 |
Network Cards:
| Network Management Module |
Additional Information:
Reference Documents:
| Document: |
CISCO-ENERGYWISE-MIB_my.txt |
| Version: |
200901080000Z |
| Sections: |
Not Available
|
| URL: |
Not Available
|
| Document: |
CISCO-ENTITY-SENSOR-MIB.mib |
| Version: |
200509080000Z |
| Sections: |
Not Available
|
| URL: |
Not Available
|
| Document: |
CISCO-ENVMON-MIB.mib |
| Version: |
200311250000Z |
| Sections: |
Not Available
|
| URL: |
Not Available
|
Clivet Chiller
| Manufacturer: |
Clivet |
| Device Type: |
Chiller |
| Family: |
Not Available
|
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
PC21L001GB-00 Comunication protocol - Modbus Sheen R32 1702624599328 |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
ComAp Generator InteliLite NT MRS
| Manufacturer: |
ComAp |
| Device Type: |
Generator |
| Family: |
InteliLite NT MRS |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
| Modbus RTU over RS485 |
| Modbus RTU over RS232 |
Additional Information:
Reference Documents:
| Document: |
IL-NT-MRS-2-2-Reference-Guide-r4.pdf |
| Version: |
2.2 ,August 2019 |
| Sections: |
Communication object list (pgs.112-116) |
| URL: |
Not Available
|
| Document: |
InteliLite NT MRS 16.TXT |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
Cooltera/CoolIT CRAC FS400/CHx750
| Manufacturer: |
Cooltera/CoolIT |
| Device Type: |
CRAC |
| Family: |
FS400/CHx750 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
| The SNMP MIB and DDF supports the Cooltera FS400 and CoolIT CHx750 devices. |
Reference Documents:
| Document: |
CHx750v5.mib |
| Version: |
5 |
| Sections: |
Not Available
|
| URL: |
Not Available
|
Cummins ATS PowerCommand
| Manufacturer: |
Cummins |
| Device Type: |
ATS |
| Family: |
PowerCommand |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Cummins-PowerCommand-1.1-1.2-2.2-2.3-3.3-modbus-register-mapping |
| Version: |
Not Available
|
| Sections: |
PC80 |
| URL: |
Not Available
|
Cummins Generator ProtoNode
| Manufacturer: |
Cummins |
| Device Type: |
Generator |
| Family: |
ProtoNode |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
| Gensets and ATSs cannot be monitored separately. ATSs are components of the genset. |
Reference Documents:
| Document: |
Sierra Monitor Protonode Startup Guide (A054T063 - Issue 6) |
| Version: |
6 |
| Sections: |
Appendix C.1.1. Modbus Registers - Genset, Appendix C.1.2. Modbus Registers - ATS |
| URL: |
N/A
|
Cummins Power Generation Automatic Transfer Switch PowerCommand 500 Series
| Manufacturer: |
Cummins Power Generation |
| Device Type: |
Automatic Transfer Switch |
| Family: |
PowerCommand 500 Series |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Modbus Register Mapping |
| Version: |
Issue 27 |
| Sections: |
PC500/550 Modbus TCP Register Map - Generator Set (Page 412-413) |
| URL: |
Not Available
|
Cummins Power Generation Generator PCC 1301/PowerCommand 1.x
| Manufacturer: |
Cummins Power Generation |
| Device Type: |
Generator |
| Family: |
PCC 1301/PowerCommand 1.x |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Cummins Power Generation Generator PowerCommand 500 Series
| Manufacturer: |
Cummins Power Generation |
| Device Type: |
Generator |
| Family: |
PowerCommand 500 Series |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Modbus Register Mapping |
| Version: |
Issue 27 |
| Sections: |
PC500/550 Modbus TCP Register Map - Generator Set (Page 411 -412) |
| URL: |
Not Available
|
Cummins Power Generation Generator PowerCommand ModLon II Gateway
| Manufacturer: |
Cummins Power Generation |
| Device Type: |
Generator |
| Family: |
PowerCommand ModLon II Gateway |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
| PowerCommand ModLon II Gateway |
Additional Information:
| Current DDF version only supports 1 genset. For additional genset support, please
contact support at https://app.ecostruxureit.com/request |
Reference Documents:
| Document: |
C673 ModLon II Instruction Sheet |
| Version: |
9-2004 |
| Sections: |
Table 9. - PowerCommand Genset (CCM-G), Table 10. - PowerCommand Automatic Transfer
Switch CCM-T |
| URL: |
N/A
|
Cummins Power Generation Generator PowerCommand
| Manufacturer: |
Cummins Power Generation |
| Device Type: |
Generator |
| Family: |
PowerCommand |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
CyberPower ATS CyberPower_ATS
| Manufacturer: |
CyberPower |
| Device Type: |
ATS |
| Family: |
CyberPower_ATS |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
CyberPower_MIB_v2.9 |
| Version: |
2.9 |
| Sections: |
ATS (1.3.6.1.4.1.3808.1.1.5) |
| URL: |
Not Available
|
CyberPower ATS CyberPower ATS
| Manufacturer: |
CyberPower |
| Device Type: |
ATS |
| Family: |
CyberPower ATS |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
| DDF has been Created for CyberPower’s ATSs do use the ePDU/ePDU2 OIDs instead of the
dedicated ats OIDs for sensors |
Reference Documents:
| Document: |
CyberPower_MIB_v2.9 |
| Version: |
2.9 |
| Sections: |
ePDU2 (1.3.6.1.4.1.3808.1.1.6) |
| URL: |
Not Available
|
CyberPower RPDU PDU81xxx
| Manufacturer: |
CyberPower |
| Device Type: |
RPDU |
| Family: |
PDU81xxx |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
CyberPower_MIB_v2.9.MIB |
| Version: |
2.9 |
| Sections: |
ePDU2 (.1.3.6.1.4.1.3808.1.1.6) |
| URL: |
Not Available
|
CyberPower UPS CyberPower_UPS
| Manufacturer: |
CyberPower |
| Device Type: |
UPS |
| Family: |
CyberPower_UPS |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Cyberex PDU Series PDM II
| Manufacturer: |
Cyberex |
| Device Type: |
PDU |
| Family: |
Series PDM II |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Cyberex PDM II Series Owner’s/Operator’s Manual |
| Version: |
05/17/10 Rev.G |
| Sections: |
Appendix B: Modbus Register Map (pgs.58-61) |
| URL: |
Not Available
|
DB Power Electronics UPS 120KVA
| Manufacturer: |
DB Power Electronics |
| Device Type: |
UPS |
| Family: |
120KVA |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
Additional Information:
Reference Documents:
| Document: |
Dbpemib.mib |
| Version: |
2.0.0 |
| Sections: |
upsIdent (.1.3.6.1.4.1.5763.1.1)
upsBattery (.1.3.6.1.4.1.5763.1.2)
upsInput (.1.3.6.1.4.1.5763.1.3)
upsOutput (.1.3.6.1.4.1.5763.1.4)
upsBypass (.1.3.6.1.4.1.5763.1.5)
upsWellKnownAlarms (.1.3.6.1.4.1.5763.1.6)
|
| URL: |
Not Available
|
Daxten RPDU HPDU
| Manufacturer: |
Daxten |
| Device Type: |
RPDU |
| Family: |
HPDU |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Deep Sea Electronics Genset Control Module 72xx, 73xx, 61xx, 74xx MkII (GenComm)
| Manufacturer: |
Deep Sea Electronics |
| Device Type: |
Genset Control Module |
| Family: |
72xx, 73xx, 61xx, 74xx MkII (GenComm) |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
GenComm standard for use with generating set control equipment |
| Version: |
2.156, 25 May 2017 |
| Sections: |
Not Available
|
| URL: |
Not Available
|
Deep Sea Electronics Genset Control Module 7450 (GenComm)
| Manufacturer: |
Deep Sea Electronics |
| Device Type: |
Genset Control Module |
| Family: |
7450 (GenComm) |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
GenComm standard for use with generating set control equipment |
| Version: |
2.156, 25 May 2017 |
| Sections: |
Not Available
|
| URL: |
Not Available
|
Deif A/S Generator AGC Series
| Manufacturer: |
Deif A/S |
| Device Type: |
Generator |
| Family: |
AGC Series |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Options H2 and H9 Modbus Communication |
| Version: |
4189340442O |
| Sections: |
Measurement Table (read only) (pgs.43-54), Alarm and Status Table (read only) (pgs.62-88) |
| URL: |
Not Available
|
Dell Server iDRAC
| Manufacturer: |
Dell |
| Device Type: |
Server |
| Family: |
iDRAC |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Delta Energy Systems System Level Controller PSC 1000
| Manufacturer: |
Delta Energy Systems |
| Device Type: |
System Level Controller |
| Family: |
PSC 1000 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
AGENT2000_1_01 |
| Version: |
1.01 |
| Sections: |
Not Available
|
| URL: |
Not Available
|
Denco / Fläkt Group CRAC Multi-DENCO, A-Version
| Manufacturer: |
Denco / Fläkt Group |
| Device Type: |
CRAC |
| Family: |
Multi-DENCO, A-Version |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Denco C5-12 Controller (Carel pcoWeb) |
Additional Information:
Reference Documents:
| Document: |
CAREL-dencoccu-MIB |
| Version: |
201308151024Z |
| Sections: |
Not Available
|
| URL: |
Not Available
|
ELNet / FENIKS PRO Ltd. Power Meter LTE Power Meter
| Manufacturer: |
ELNet / FENIKS PRO Ltd. |
| Device Type: |
Power Meter |
| Family: |
LTE Power Meter |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Eaton ATS ATC-900
| Manufacturer: |
Eaton |
| Device Type: |
ATS |
| Family: |
ATC-900 |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Eaton EMS Powerware
| Manufacturer: |
Eaton |
| Device Type: |
EMS |
| Family: |
Powerware |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
Additional Information:
Reference Documents:
| Document: |
RackMonitor-MIB.mib |
| Version: |
v2.00 10-May-2007 |
| Sections: |
rmIdent (1.3.6.1.4.1.534.6.7.1.1.1)
sensorMonitor (.1.3.6.1.4.1.534.6.7.1.1.3)
|
| URL: |
Not Available
|
Eaton Inverter Eaton System Controllers
| Manufacturer: |
Eaton |
| Device Type: |
Inverter |
| Family: |
Eaton System Controllers |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| SC300 |
| Firmware Versions: |
| boot: 1.19.4; interface: 99; hardware: 2.123; lcd: 2.100; appbuild: 7edd8fc |
Additional Information:
Reference Documents:
| Document: |
RpsSc300Mib |
| Version: |
Not Available
|
| Sections: |
1.3.6.1.4.1.1918.2.14.* |
| URL: |
Not Available
|
Eaton Inverter Eaton System Controllers
| Manufacturer: |
Eaton |
| Device Type: |
Inverter |
| Family: |
Eaton System Controllers |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
RPS-SC200-MIB.txt |
| Version: |
Not Available
|
| Sections: |
1.3.6.1.4.1.1918.2.13.* |
| URL: |
Not Available
|
Eaton EMS-PDU
| Manufacturer: |
Eaton |
| Device Type: |
Not Available
|
| Family: |
EMS-PDU |
| Protocol: |
SNMP |
Models Tested:
| EMS-PDU |
| EMS-PDU with Breaker |
Network Cards:
| Power Xpert Gateway Series 1000 Card |
Additional Information:
Reference Documents:
Eaton RPDU EPDU
| Manufacturer: |
Eaton |
| Device Type: |
RPDU |
| Family: |
EPDU |
| Protocol: |
SNMP |
Models Tested:
| eAM002 |
| eMAA13 |
| eSWA04 |
| EMIB08 |
| EMOB20 |
| EMI101-10 |
| EMI102-10 |
| EMI104-10 |
| EMA107-10 |
| EMI310-10 |
| EMAT08-10 |
Network Cards:
| Network Management Module |
| Firmware Versions: |
| 00.00.0024 |
| 00.10.0001 |
| 00.12.0001 |
| 01.00.0026 |
| 01.00.0031 |
| 01.00.0034 |
| 02.00.0036 |
| 02.00.0038 |
| 02.00.0041 |
| 02.00.0053 |
Additional Information:
Reference Documents:
| Document: |
EATON-EPDU-MIB.mib |
| Version: |
201409291200Z |
| Sections: |
eatonEpdu (.1.3.6.1.4.1.534.6.6.7)
units (.1.3.6.1.4.1.534.6.6.7.1)
inputs (.1.3.6.1.4.1.534.6.6.7.3)
groups (.1.3.6.1.4.1.534.6.6.7.5)
outlets (.1.3.6.1.4.1.534.6.6.7.6)
environmental (.1.3.6.1.4.1.534.6.6.7.7)
|
| URL: |
Not Available
|
Eaton Corporation Power Meter DigiTrip 1150 PXG
| Manufacturer: |
Eaton Corporation |
| Device Type: |
Power Meter |
| Family: |
DigiTrip 1150 PXG |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
MNA03669- Register number details per specifications |
| Version: |
Not Available
|
| Sections: |
Breakers-Digitrip 1150 (cells E9:J33) |
| URL: |
Not Available
|
Eaton Corporation Protective Relay FP 5000-series
| Manufacturer: |
Eaton Corporation |
| Device Type: |
Protective Relay |
| Family: |
FP 5000-series |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Power Xpert Gateway 400/600 |
| Version: |
Not Available
|
| Sections: |
FP5000(pgs.1,5) |
| URL: |
Not Available
|
Eaton Corporation Power Meter Power Xpert 4000/6000/8000
| Manufacturer: |
Eaton Corporation |
| Device Type: |
Power Meter |
| Family: |
Power Xpert 4000/6000/8000 |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Power Xpert Registers |
| Version: |
IB02601003E |
| Sections: |
B.1. Standard Modbus Register Map (pgs.185-190) |
| URL: |
Not Available
|
Eaton Corporation UPS Powerware
| Manufacturer: |
Eaton Corporation |
| Device Type: |
UPS |
| Family: |
Powerware |
| Protocol: |
SNMP |
Models Tested:
| 5PX 1500 |
| 5P 1500 R Li-ion |
| PXGX 2000 Eaton 9315 |
| PXGX 2000 Powerware Plus |
| PXGX 2000 Eaton UPS |
| PXGX 2000 Eaton 9390 |
| 9SX 3000iR |
| PXGMS UPS + EATON 93PM |
Network Cards:
| Eaton Power Xpert Gateway UPS X-Slot Card |
| Firmware Versions: |
| INV: 07 |
| 1.06.0018 |
| INV: 1.10 NET: 1.4.2.1-ups |
| INV: 1.14 NET: 1.2.0-ups |
| INV: 1.28 NET: 1.4.2.1-ups |
| INV: 2.12 NET: 2.4.0.1-ups |
Additional Information:
Reference Documents:
Eaton Corporation / Pulizzi Engineering Rack PDU Switched ePDU
| Manufacturer: |
Eaton Corporation / Pulizzi Engineering |
| Device Type: |
Rack PDU |
| Family: |
Switched ePDU |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Elcos Generator Elcos Generator
| Manufacturer: |
Elcos |
| Device Type: |
Generator |
| Family: |
Elcos Generator |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
DCE DDF: elcos_generator.xml |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
Electro Industries/GaugeTech Inc. Power Meter Shark 100 Switchboard Power Meter
| Manufacturer: |
Electro Industries/GaugeTech Inc. |
| Device Type: |
Power Meter |
| Family: |
Shark 100 Switchboard Power Meter |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
| Modbus RTU over RS485 |
| Modbus TCP over Ethernet |
Additional Information:
Reference Documents:
| Document: |
Shark 100/100T/100B/100BT/50/50B |
| Version: |
V.1.34, February 4, 2021 |
| Sections: |
Shark(R) 100 Meter Modbus Map (pgs. 175-181) |
| URL: |
Not Available
|
Electro Industries/GaugeTech Inc. Power Meter Shark 200 Switchboard Power Meter
| Manufacturer: |
Electro Industries/GaugeTech Inc. |
| Device Type: |
Power Meter |
| Family: |
Shark 200 Switchboard Power Meter |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
| Modbus RTU over RS485 |
| Modbus TCP over Ethernet |
Additional Information:
Reference Documents:
| Document: |
Shark 200/200T |
| Version: |
V.1.30, July 3, 2020 |
| Sections: |
Shark(R) 200 Meter Modbus Register Map (pgs. 252-294) |
| URL: |
Not Available
|
Eltek system level controller Eltek_SmartPacks
| Manufacturer: |
Eltek |
| Device Type: |
system level controller |
| Family: |
Eltek_SmartPacks |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Emerson / Liebert / Vertiv UPS Liebert APM
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
UPS |
| Family: |
Liebert APM |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Liebert(R) IntelliSlot(R) Modbus 485, Modbus IP and BACnet IP, Reference Guide |
| Version: |
Not Available
|
| Sections: |
3.3 UPS Systems Tables 44-46 (pgs.135-140) |
| URL: |
Not Available
|
| Document: |
ModbusDataMap.txt |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
Emerson / Liebert / Vertiv CRAC CR
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
CRAC |
| Family: |
CR |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 8.2.3.0 |
Additional Information:
Reference Documents:
Emerson / Liebert / Vertiv CRAC CRD
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
CRAC |
| Family: |
CRD |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 7.8.0.0 |
Additional Information:
Reference Documents:
Emerson / Liebert / Vertiv UPS eXM M/S/R
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
UPS |
| Family: |
eXM M/S/R |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 7.7.0.0 |
Additional Information:
Reference Documents:
Emerson / Liebert / Vertiv UPS EXS
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
UPS |
| Family: |
EXS |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 7.8.0.0 |
Additional Information:
Reference Documents:
Emerson / Liebert / Vertiv UPS GXT4
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
UPS |
| Family: |
GXT4 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 7.8.0.0 |
Additional Information:
Reference Documents:
Emerson / Liebert / Vertiv UPS GXT5
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
UPS |
| Family: |
GXT5 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot RDU101 Card |
| Firmware Versions: |
| 1.2.2.0 |
Additional Information:
Reference Documents:
Emerson / Liebert / Vertiv UPS NX
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
UPS |
| Family: |
NX |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Web Card |
| Firmware Versions: |
| 5.010.1 |
Additional Information:
Reference Documents:
Emerson / Liebert / Vertiv UPS NX (225-600k)
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
UPS |
| Family: |
NX (225-600k) |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 7.5.1.0 |
Additional Information:
Reference Documents:
Emerson / Liebert / Vertiv UPS NXL
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
UPS |
| Family: |
NXL |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IS-UNITY-DP |
| Firmware Versions: |
| 6.1.0.0 |
Additional Information:
Reference Documents:
Emerson / Liebert / Vertiv UPS NXR
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
UPS |
| Family: |
NXR |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Web Card |
| Firmware Versions: |
| 5.180.1 |
| 5.280.2 |
Additional Information:
Reference Documents:
Emerson / Liebert / Vertiv UPS Npower
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
UPS |
| Family: |
Npower |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| OpenComms Web Card |
| Firmware Versions: |
| 2.200.0 |
Additional Information:
Reference Documents:
Emerson / Liebert / Vertiv UPS PowerSure Interactive 5
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
UPS |
| Family: |
PowerSure Interactive 5 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 8.2.0.0 |
Additional Information:
Reference Documents:
Emerson / Liebert / Vertiv UPS Series 600 / Series 610
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
UPS |
| Family: |
Series 600 / Series 610 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Web Card |
| Firmware Versions: |
| 3.120.6 |
| OpenComms Web Card |
| Firmware Versions: |
| 3.020.0 |
Additional Information:
Reference Documents:
Emerson / Liebert / Vertiv UPS Series 610 SMS
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
UPS |
| Family: |
Series 610 SMS |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Web/485 Card |
| Firmware Versions: |
| 3.120.7 |
Additional Information:
Reference Documents:
Emerson / Liebert / Vertiv UPS Series 7200
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
UPS |
| Family: |
Series 7200 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Web/485 Card |
| Firmware Versions: |
| 3.120.7 |
| 5.2A0.2 |
Additional Information:
Reference Documents:
Emerson / Liebert / Vertiv UPS UPStation GXT
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
UPS |
| Family: |
UPStation GXT |
| Protocol: |
SNMP |
Models Tested:
| GXT2-1000RT120 |
| GXT3-3000RT120 |
| GXT3-3000RT230 |
Network Cards:
| IntelliSlot Web Card |
| Firmware Versions: |
| 3.100.2 |
| 5.200.0 |
| 5.300.0 |
Additional Information:
Reference Documents:
Enlogic PDU Edge Series
| Manufacturer: |
Enlogic |
| Device Type: |
PDU |
| Family: |
Edge Series |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
Additional Information:
Reference Documents:
Enlogic PDU Advantage Series
| Manufacturer: |
Enlogic |
| Device Type: |
PDU |
| Family: |
Advantage Series |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
| Firmware Versions: |
| 1.0.6.1 |
Additional Information:
Reference Documents:
| Document: |
1606761202-Enlogic_2.0_v1_0.mib |
| Version: |
202010300000Z |
| Sections: |
pduNamePlate (.1.3.6.1.4.1.38446.1.1)
pduUnit (.1.3.6.1.4.1.38446.1.2)
pduInputPhase (.1.3.6.1.4.1.38446.1.3)
pduCircuitBreaker (.1.3.6.1.4.1.38446.1.4)
pduOutlet (.1.3.6.1.4.1.38446.1.5)
pduExternalSensor (.1.3.6.1.4.1.38446.1.6)
|
| URL: |
https://www.enlogic.com/public/assets/images/1606761202-Enlogic_2.0_v1_0.mib
|
Enlogic PDU Legacy
| Manufacturer: |
Enlogic |
| Device Type: |
PDU |
| Family: |
Legacy |
| Protocol: |
SNMP |
Models Tested:
| EN1111 |
| EN1183 |
| EN4001 |
| EN6109 |
| EN6113 |
| EZ1157 |
Network Cards:
| Network Management Module |
| Firmware Versions: |
| 6.ca |
| 6.d0 |
| 7.08 |
| 7.11T26 |
| 7.12R31 |
| 7.12R3F |
| 7.12T39 |
| 7.80T15 |
Additional Information:
Reference Documents:
| Document: |
1590139060-Enlogic_legacy_mib.mib |
| Version: |
201506180000Z |
| Sections: |
pduNamePlate (.1.3.6.1.4.1.38446.1.1)
pduUnit (.1.3.6.1.4.1.38446.1.2)
pduInputPhase (.1.3.6.1.4.1.38446.1.3)
pduCircuitBreaker (.1.3.6.1.4.1.38446.1.4)
pduOutlet (.1.3.6.1.4.1.38446.1.5)
pduExternalSensor (.1.3.6.1.4.1.38446.1.6)
|
| URL: |
https://www.enlogic.com/public/assets/images/1590139060-Enlogic_legacy_mib.mib
|
Enlogic Power Meter Inline
| Manufacturer: |
Enlogic |
| Device Type: |
Power Meter |
| Family: |
Inline |
| Protocol: |
SNMP |
Models Tested:
| EZ1152 |
| EZ1154 |
| EZ1254 |
| EZ1255 |
Network Cards:
| Network Management Module |
| Firmware Versions: |
| 9.10 |
| 9.10R02 |
| 7.12R31 |
Additional Information:
Reference Documents:
| Document: |
1590139060-Enlogic_legacy_mib.mib |
| Version: |
201506180000Z |
| Sections: |
pduNamePlate (.1.3.6.1.4.1.38446.1.1)
pduUnit (.1.3.6.1.4.1.38446.1.2)
pduInputPhase (.1.3.6.1.4.1.38446.1.3)
pduCircuitBreaker (.1.3.6.1.4.1.38446.1.4)
pduOutlet (.1.3.6.1.4.1.38446.1.5)
pduExternalSensor (.1.3.6.1.4.1.38446.1.6)
|
| URL: |
https://www.enlogic.com/public/assets/images/1590139060-Enlogic_legacy_mib.mib
|
FG Wilson Generator PowerWizard 2.x / 3.x
| Manufacturer: |
FG Wilson |
| Device Type: |
Generator |
| Family: |
PowerWizard 2.x / 3.x |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
PowerWizard 2.0/3.0 Modbus Applications Guide |
| Version: |
Not Available
|
| Sections: |
Data Link Layer - Supported Function Codes |
| URL: |
Not Available
|
Fronius Inverter Symo Hybrid
| Manufacturer: |
Fronius |
| Device Type: |
Inverter |
| Family: |
Symo Hybrid |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
GE UPS LP
| Manufacturer: |
GE |
| Device Type: |
UPS |
| Family: |
LP |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
GESINGLEUPSv024 |
| Version: |
2.4 |
| Sections: |
Not Available
|
| URL: |
Not Available
|
Geist RPDU Upgradeable / R-Series v5.0
| Manufacturer: |
Geist |
| Device Type: |
RPDU |
| Family: |
Upgradeable / R-Series v5.0 |
| Protocol: |
SNMP |
Models Tested:
| EG2RCUC206-103P8BPS6-OD-IF-02-IP44 |
| MGU3EHW1-48MI13-3PS56B2A10-S-A |
| EGRCMBN243-102PH6PS56-OD-IP44 |
Network Cards:
Additional Information:
Reference Documents:
| Document: |
geist_v5.mib |
| Version: |
201906060000Z |
| Sections: |
pduMainTable (.1.3.6.1.4.1.21239.5.2.3.1)
pduPhaseTable (.1.3.6.1.4.1.21239.5.2.3.2)
pduBreakerTable (.1.3.6.1.4.1.21239.5.2.3.3)
tempSensorTable (.1.3.6.1.4.1.21239.5.2.4)
airFlowSensorTable (.1.3.6.1.4.1.21239.5.2.5)
t3hdSensorTable (.1.3.6.1.4.1.21239.5.2.8)
thdSensorTable (.1.3.6.1.4.1.21239.5.2.9)
|
| URL: |
Not Available
|
Geist RPDU IMD PDU
| Manufacturer: |
Geist |
| Device Type: |
RPDU |
| Family: |
IMD PDU |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
geist_imd_mib.mib |
| Version: |
201209110000Z |
| Sections: |
dewPointSensorTable (.1.3.6.1.4.1.21239.5.2.6)
ccatSensorTable (.1.3.6.1.4.1.21239.5.2.7)
rpmSensorTable (.1.3.6.1.4.1.21239.5.2.10)
|
| URL: |
Not Available
|
| Document: |
geist_v5.mib |
| Version: |
201906060000Z |
| Sections: |
pduMainTable (.1.3.6.1.4.1.21239.5.2.3.1)
pduPhaseTable (.1.3.6.1.4.1.21239.5.2.3.2)
pduBreakerTable (.1.3.6.1.4.1.21239.5.2.3.3)
tempSensorTable (.1.3.6.1.4.1.21239.5.2.4)
airFlowSensorTable (.1.3.6.1.4.1.21239.5.2.5)
t3hdSensorTable (.1.3.6.1.4.1.21239.5.2.8)
thdSensorTable (.1.3.6.1.4.1.21239.5.2.9)
|
| URL: |
Not Available
|
Generac Genset Control Module Power Zone Pro
| Manufacturer: |
Generac |
| Device Type: |
Genset Control Module |
| Family: |
Power Zone Pro |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
PowerZone_Modbus_Map.xlsx |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
Generac Generator SD100 H-Panel
| Manufacturer: |
Generac |
| Device Type: |
Generator |
| Family: |
SD100 H-Panel |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Modbus H panel - Charter Monitoring Points |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
Green Revolution Cooling CRAC ICEraQ Micro 24U
| Manufacturer: |
Green Revolution Cooling |
| Device Type: |
CRAC |
| Family: |
ICEraQ Micro 24U |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
GRC.xlsx |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
Grundfos Pump CIM-500
| Manufacturer: |
Grundfos |
| Device Type: |
Pump |
| Family: |
CIM-500 |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
| This DDF assumes teh default register offset of 0 (zero) for all addresses above 00100.
If you see strange/incorrect data try setting the offset back to default per the devices
documentation. |
Reference Documents:
HW group s.r.o. SNMP Thermometer HWg-STE
| Manufacturer: |
HW group s.r.o. |
| Device Type: |
SNMP Thermometer |
| Family: |
HWg-STE |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
STE-MIB |
| Version: |
v.1.03, 17 Jul 2013 |
| Sections: |
.1.3.6.1.4.1.21796.4.1.* |
| URL: |
Not Available
|
HW group s.r.o. SNMP Thermometer STE2
| Manufacturer: |
HW group s.r.o. |
| Device Type: |
SNMP Thermometer |
| Family: |
STE2 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Hager Power Meter Multifunction Power Meter - JKM01
| Manufacturer: |
Hager |
| Device Type: |
Power Meter |
| Family: |
Multifunction Power Meter - JKM01 |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Hager - JKM01_MODBUS_REGISTERS_6LE005454A.xlsx |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
Hewlett-Packard Enterprise PDU Modular
| Manufacturer: |
Hewlett-Packard Enterprise |
| Device Type: |
PDU |
| Family: |
Modular |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
CPQPOWER_MIB |
| Version: |
1.76 |
| Sections: |
1.3.6.1.4.1.232.165.5.* |
| URL: |
Not Available
|
Hewlett-Packard Enterprise Rack PDU v2
| Manufacturer: |
Hewlett-Packard Enterprise |
| Device Type: |
Rack PDU |
| Family: |
v2 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
CPQPOWER_MIB |
| Version: |
1.76 |
| Sections: |
1.3.6.1.4.1.232.165.7.* |
| URL: |
Not Available
|
Hewlett-Packard Enterprise Rack PDU v1
| Manufacturer: |
Hewlett-Packard Enterprise |
| Device Type: |
Rack PDU |
| Family: |
v1 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
CPQPOWER_MIB |
| Version: |
1.76 |
| Sections: |
1.3.6.1.4.1.232.165.2.* |
| URL: |
Not Available
|
Hewlett-Packard Enterprise Rack PDU HPE G2
| Manufacturer: |
Hewlett-Packard Enterprise |
| Device Type: |
Rack PDU |
| Family: |
HPE G2 |
| Protocol: |
SNMP |
Models Tested:
| HPE Metered Switched 3Ph 17.3kVA/60309 4-wire 48A/208V PDU (P9S23A) |
Network Cards:
| HP PDU Management Module |
| Firmware Versions: |
| 2.0.0.M |
Additional Information:
Reference Documents:
| Document: |
CPQPOWER-MIB |
| Version: |
1.82 |
| Sections: |
1.3.6.1.4.1.232.165.11.* |
| URL: |
Not Available
|
| Document: |
CPQHOST-MIB |
| Version: |
Not Available
|
| Sections: |
|
| URL: |
Not Available
|
Himoinsa Generator CEM/CEC/CEA Genset Control Unit
| Manufacturer: |
Himoinsa |
| Device Type: |
Generator |
| Family: |
CEM/CEC/CEA Genset Control Unit |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
| CCLan Modbus Option Module |
Additional Information:
Reference Documents:
| Document: |
CAN/LAN MODBUS: CCLAN: Opción de comunicaciones por protocolo MODBus IP |
| Version: |
1.4_es |
| Sections: |
section 2.2, "Mapa de registros" (pgs.8-16) |
| URL: |
Not Available
|
Hiref SpA CRAC NADR
| Manufacturer: |
Hiref SpA |
| Device Type: |
CRAC |
| Family: |
NADR |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Hiref HiNode (Carel pcoWeb) |
Additional Information:
Reference Documents:
| Document: |
CAREL-std-air-cond-MIB |
| Version: |
201005190920Z |
| Sections: |
Not Available
|
| URL: |
Not Available
|
Huawei UPS Huawei UPS MIB
| Manufacturer: |
Huawei |
| Device Type: |
UPS |
| Family: |
Huawei UPS MIB |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
| Firmware Versions: |
| V100R003C01SPC410 |
Additional Information:
| DDF supports up to 2 UPSs in parallel. |
Reference Documents:
| Document: |
HUAWEI_UPS_MIB.mib |
| Version: |
201210240000Z |
| Sections: |
hwUpsSystem (.1.3.6.1.4.1.2011.6.174.1.1)
hwUpsDevice (.1.3.6.1.4.1.2011.6.174.1.2)
hwUpsInput (.1.3.6.1.4.1.2011.6.174.1.3)
hwUpsOutput (.1.3.6.1.4.1.2011.6.174.1.4)
hwUpsBypass (.1.3.6.1.4.1.2011.6.174.1.5)
hwUpsBattery (.1.3.6.1.4.1.2011.6.174.1.6)
|
| URL: |
Not Available
|
IMARI Generic Device UFM-700 Series
| Manufacturer: |
IMARI |
| Device Type: |
Generic Device |
| Family: |
UFM-700 Series |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
| This DDF was created using DCE DDF imari_ufm_700_series_flow_meter.xml version 2 |
Reference Documents:
| Document: |
imari_ufm_700_series_flow_meter.xml |
| Version: |
2 |
| Sections: |
Not Available
|
| URL: |
Not Available
|
ITWatchDogs (Vertiv Geist) EMS SuperGoose II
| Manufacturer: |
ITWatchDogs (Vertiv Geist) |
| Device Type: |
EMS |
| Family: |
SuperGoose II |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
Additional Information:
Reference Documents:
| Document: |
itw_mibv3.mib |
| Version: |
200801100000Z |
| Sections: |
.1.3.6.1.4.1.17373.3.* |
| URL: |
Not Available
|
ITWatchDogs (Vertiv Geist) EMS WxGoos
| Manufacturer: |
ITWatchDogs (Vertiv Geist) |
| Device Type: |
EMS |
| Family: |
WxGoos |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
Additional Information:
Reference Documents:
| Document: |
itw_mib.mib |
| Version: |
200709040000Z |
| Sections: |
.1.3.6.1.4.1.17373.2.* |
| URL: |
Not Available
|
Innovative Circuit Technology Ltd. Modular UPS Power System
| Manufacturer: |
Innovative Circuit Technology Ltd. |
| Device Type: |
Modular UPS |
| Family: |
Power System |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
ICT-POWERSYSTEM-MIB |
| Version: |
v.1.06, 24 Jan 2025 |
| Sections: |
.1.3.6.1.4.1.39145.* |
| URL: |
Not Available
|
Intesis CRAC Fujitsu RAC/VRF Gateway
| Manufacturer: |
Intesis |
| Device Type: |
CRAC |
| Family: |
Fujitsu RAC/VRF Gateway |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Janitza Power Meter UMG96
| Manufacturer: |
Janitza |
| Device Type: |
Power Meter |
| Family: |
UMG96 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
Additional Information:
| Like pCOWeb devices, OIDs are shared across different models but measure different
parameters |
Reference Documents:
| Document: |
UMG96RM_09092013.mib |
| Version: |
09092013 |
| Sections: |
rmsPhase (.1.3.6.1.4.1.34278.1.*)
rmsSum (.1.3.6.1.4.1.34278.2.*)
energyPhase (.1.3.6.1.4.1.34278.3.*)
energySum (.1.3.6.1.4.1.34278.4.*)
thd (.1.3.6.1.4.1.34278.5.*)
misc (.1.3.6.1.4.1.34278.6.*)
|
| URL: |
https://www.janitza.com/snmpmib-download.html
|
Janitza Electronics GmbH Power Meter UMG 507
| Manufacturer: |
Janitza Electronics GmbH |
| Device Type: |
Power Meter |
| Family: |
UMG 507 |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
| discontinued by manufacturer |
Reference Documents:
| Document: |
UMG507 Register map |
| Version: |
Software Release 0.934, November 18 2004 |
| Sections: |
Modbus Address List (pgs.1,4,) |
| URL: |
Not Available
|
Janitza Electronics GmbH Power Meter UMG 604
| Manufacturer: |
Janitza Electronics GmbH |
| Device Type: |
Power Meter |
| Family: |
UMG 604 |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Janitza Electronics GmbH Power Meter UMG 96RM
| Manufacturer: |
Janitza Electronics GmbH |
| Device Type: |
Power Meter |
| Family: |
UMG 96RM |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Juniper Networks Ethernet switch Ethernet switches
| Manufacturer: |
Juniper Networks |
| Device Type: |
Ethernet switch |
| Family: |
Ethernet switches |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
JUNIPER-SMI |
| Version: |
201703010000Z |
| Sections: |
1.3.6.1.4.1.2636.* |
| URL: |
Not Available
|
Kamstrup Heat Meter MULTICAL
| Manufacturer: |
Kamstrup |
| Device Type: |
Heat Meter |
| Family: |
MULTICAL |
| Protocol: |
MODBUS |
Models Tested:
| MULTICAL 62 |
| MULTICAL 601 |
| MULTICAL 602 |
| MULTICAL 801 |
Network Cards:
Additional Information:
Reference Documents:
Kidde-Fenwal Inc. Generic ARIES
| Manufacturer: |
Kidde-Fenwal Inc. |
| Device Type: |
Generic |
| Family: |
ARIES |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
kidde-fenwal_ARIES.pdf |
| Version: |
Not Available
|
| Sections: |
Pages 14-19 |
| URL: |
Not Available
|
Kohler Power Systems Generator Decision Maker
| Manufacturer: |
Kohler Power Systems |
| Device Type: |
Generator |
| Family: |
Decision Maker |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
| Modbus RTU over RS485 |
| Modbus TCP over Ethernet |
Additional Information:
Reference Documents:
| Document: |
tp6113.pdf |
| Version: |
Not Available
|
| Sections: |
Modbus Registers (pgs. 47-60) |
| URL: |
Not Available
|
Komfovent CRAC Verso-CF
| Manufacturer: |
Komfovent |
| Device Type: |
CRAC |
| Family: |
Verso-CF |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
MODBUS_C5_manual_EN.pdf |
| Version: |
Not Available
|
| Sections: |
Functions, Alarms, Monitoring Data, Monitoring Data Zone 1 and Monitoring Data Zone
2 Tables |
| URL: |
Not Available
|
Legrand UPS Daker DK - Daker DK Plus - Keor LP - Keor S
| Manufacturer: |
Legrand |
| Device Type: |
UPS |
| Family: |
Daker DK - Daker DK Plus - Keor LP - Keor S |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Legrand UPS Daker DK - Daker DK Plus - Keor LP - Keor S
| Manufacturer: |
Legrand |
| Device Type: |
UPS |
| Family: |
Daker DK - Daker DK Plus - Keor LP - Keor S |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Legrand UPS Dhea - Whad 800/1000/1500/2000/2500 - Whad CAB - Megaline
| Manufacturer: |
Legrand |
| Device Type: |
UPS |
| Family: |
Dhea - Whad 800/1000/1500/2000/2500 - Whad CAB - Megaline |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Legrand UPS Niky - Niky S - Keor Line RT
| Manufacturer: |
Legrand |
| Device Type: |
UPS |
| Family: |
Niky - Niky S - Keor Line RT |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Lenovo Server ThinkSystem series
| Manufacturer: |
Lenovo |
| Device Type: |
Server |
| Family: |
ThinkSystem series |
| Protocol: |
REDFISH |
Models Tested:
Network Cards:
| XClarity Controller (XCC) BMC |
Additional Information:
Reference Documents:
Lenovo RPDU Lenovo RPDU
| Manufacturer: |
Lenovo |
| Device Type: |
RPDU |
| Family: |
Lenovo RPDU |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
| Firmware Versions: |
| 02.00.0038 |
Additional Information:
Reference Documents:
| Document: |
EATON-EPDU-MIB.mib |
| Version: |
201409291200Z |
| Sections: |
eatonEpdu (.1.3.6.1.4.1.534.6.6.7)
units (.1.3.6.1.4.1.534.6.6.7.1)
inputs (.1.3.6.1.4.1.534.6.6.7.3)
groups (.1.3.6.1.4.1.534.6.6.7.5)
outlets (.1.3.6.1.4.1.534.6.6.7.6)
environmental (.1.3.6.1.4.1.534.6.6.7.7)
|
| URL: |
Not Available
|
Luminous UPS
| Manufacturer: |
Luminous |
| Device Type: |
UPS |
| Family: |
Not Available
|
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
| Firmware Versions: |
| 00862.04 |
Additional Information:
Reference Documents:
| Document: |
UPSmib.MIB |
| Version: |
20100560000Z |
| Sections: |
ups (.1.3.6.1.4.1.43943.1.1.*) |
| URL: |
Not Available
|
Mitsubishi UPS
| Manufacturer: |
Mitsubishi |
| Device Type: |
UPS |
| Family: |
Not Available
|
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
| In netcom-manual-rev-51.pdf, MIB is located in Appendix D, "MIBS"; pg.53 |
Reference Documents:
Mitsubishi Electric UPS 9800-series
| Manufacturer: |
Mitsubishi Electric |
| Device Type: |
UPS |
| Family: |
9800-series |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
| Niobrara MUCM (Modbus RTU over RS485) |
Additional Information:
Reference Documents:
Mitsubishi Electric UPS 9900-series
| Manufacturer: |
Mitsubishi Electric |
| Device Type: |
UPS |
| Family: |
9900-series |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
| Niobrara MUCM (Modbus RTU over RS485) |
Additional Information:
Reference Documents:
Monico Generator Monitor mCore SDR Genset 1
| Manufacturer: |
Monico |
| Device Type: |
Generator Monitor |
| Family: |
mCore SDR Genset 1 |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Monico Generator Monitor mCore SDR Genset 2
| Manufacturer: |
Monico |
| Device Type: |
Generator Monitor |
| Family: |
mCore SDR Genset 2 |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Network Technologies Incorporated (NTI) EMS ENVIROMUX-16D
| Manufacturer: |
Network Technologies Incorporated (NTI) |
| Device Type: |
EMS |
| Family: |
ENVIROMUX-16D |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
Additional Information:
Reference Documents:
Network Technologies Incorporated (NTI) EMS ENVIROMUX-2D
| Manufacturer: |
Network Technologies Incorporated (NTI) |
| Device Type: |
EMS |
| Family: |
ENVIROMUX-2D |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
Additional Information:
Reference Documents:
Network Technologies Incorporated (NTI) EMS ENVIROMUX-5D
| Manufacturer: |
Network Technologies Incorporated (NTI) |
| Device Type: |
EMS |
| Family: |
ENVIROMUX-5D |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
Additional Information:
Reference Documents:
Nortec Generator Monitor Nortec Humidifier
| Manufacturer: |
Nortec |
| Device Type: |
Generator Monitor |
| Family: |
Nortec Humidifier |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
North generic North Integrator
| Manufacturer: |
North |
| Device Type: |
generic |
| Family: |
North Integrator |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Oracle RPDU Enhanced PDU
| Manufacturer: |
Oracle |
| Device Type: |
RPDU |
| Family: |
Enhanced PDU |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
snmp_oracle_rmii.mib |
| Version: |
Not Available
|
| Sections: |
pduSystem (.1.3.6.1.4.1.2769.1.4.1)
pduTotalPower (.1.3.6.1.4.1.2769.1.4.5.1)
pduPowerInputs (.1.3.6.1.4.1.2769.1.4.5.2)
pduLines (.1.3.6.1.4.1.2769.1.4.5.3)
|
| URL: |
Not Available
|
PDI BCM Branch Circuit Monitor System II Plus (BCMSII Plus)
| Manufacturer: |
PDI |
| Device Type: |
BCM |
| Family: |
Branch Circuit Monitor System II Plus (BCMSII Plus) |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
PDI Display WaveStar Color Monitor
| Manufacturer: |
PDI |
| Device Type: |
Display |
| Family: |
WaveStar Color Monitor |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
PDI-FDI-DISPLAY-14-a.mib |
| Version: |
Revision B 27/10/2014 |
| Sections: |
pdu1 (.1.3.6.1.4.1.24436.1.5.3.2.11)
bcmskwh1 (.1.3.6.1.4.1.24436.1.5.3.2.8)
bcmskwh2 (.1.3.6.1.4.1.24436.1.5.3.3.8)
bcmskwh3 (.1.3.6.1.4.1.24436.1.5.3.4.8)
bcmskwh4 (.1.3.6.1.4.1.24436.1.5.3.5.8)
|
| URL: |
Not Available
|
PDI STS WaveStar
| Manufacturer: |
PDI |
| Device Type: |
STS |
| Family: |
WaveStar |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Wavestar_Rev4.mib |
| Version: |
February 26, 2013 |
| Sections: |
analog-values (.1.3.6.1.4.1.11273.1.2.1.1)
analog-alarms (.1.3.6.1.4.1.11273.1.2.1.2)
digital-values (.1.3.6.1.4.1.11273.1.2.1.3)
digital-alarms (.1.3.6.1.4.1.11273.1.2.1.4)
|
| URL: |
https://www.pdicorp.com/services/service-software-downloads/
|
PDI Corp. / Eaton Branch Circuit Monitor Branch Circuit Monitor System II (BCMSII)
| Manufacturer: |
PDI Corp. / Eaton |
| Device Type: |
Branch Circuit Monitor |
| Family: |
Branch Circuit Monitor System II (BCMSII) |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
| Data Acquisition Module (Modbus RTU over RS485) |
Additional Information:
Reference Documents:
PDI Corp. / Eaton Branch Circuit Monitor Branch Circuit Monitor System II Plus (BCMSII Plus)
| Manufacturer: |
PDI Corp. / Eaton |
| Device Type: |
Branch Circuit Monitor |
| Family: |
Branch Circuit Monitor System II Plus (BCMSII Plus) |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
| Data Acquisition Module (Modbus RTU over RS485) |
Additional Information:
Reference Documents:
PacketPower LLC Power Meter Modbus Ethernet Gateway, v.4
| Manufacturer: |
PacketPower LLC |
| Device Type: |
Power Meter |
| Family: |
Modbus Ethernet Gateway, v.4 |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
| Modbus Ethernet Gateway, v.4 |
Additional Information:
Reference Documents:
Panduit RPDU SmartZone G5 Series
| Manufacturer: |
Panduit |
| Device Type: |
RPDU |
| Family: |
SmartZone G5 Series |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
| Firmware Versions: |
| V3.1.1 |
Additional Information:
Reference Documents:
| Document: |
Panduit.MIB |
| Version: |
02 Feb 2021 |
| Sections: |
pdug5Ident (.1.3.6.1.4.1.19536.10.1.1)
pdug5Input (.1.3.6.1.4.1.19536.10.1.2)
pdug5Group (.1.3.6.1.4.1.19536.10.1.3)
pdug5Environment (.1.3.6.1.4.1.19536.10.1.4)
pdug5Outlet (.1.3.6.1.4.1.19536.10.1.5)
|
| URL: |
Not Available
|
Phoenix Broadband Technologies BMS PowerAgent
| Manufacturer: |
Phoenix Broadband Technologies |
| Device Type: |
BMS |
| Family: |
PowerAgent |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
pbtRootMIB.mib |
| Version: |
Jan. 9 2009 |
| Sections: |
Not Available
|
| URL: |
Not Available
|
| Document: |
pbtBatteryAgentMIB.mib |
| Version: |
Feb. 17 2009 |
| Sections: |
Not Available
|
| URL: |
Not Available
|
Phoenix Contact UPS QUINT4 DC UPS
| Manufacturer: |
Phoenix Contact |
| Device Type: |
UPS |
| Family: |
QUINT4 DC UPS |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
QUINT4-UPS/24DC/24DC/5 Uninterruptible Power Supply Datasheet |
| Version: |
2019-05-16 |
| Sections: |
Chapter 17, Attachment - Register Tables (pgs.68-84) |
| URL: |
Not Available
|
PhoenixTec Power Co. UPS UPSMate
| Manufacturer: |
PhoenixTec Power Co. |
| Device Type: |
UPS |
| Family: |
UPSMate |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
XPPC-MIB |
| Version: |
Version 2.00, May 16, 2003 |
| Sections: |
1.3.6.1.4.1.935.* |
| URL: |
Not Available
|
PowerShield Limited Battery String Monitor PowerShield8
| Manufacturer: |
PowerShield Limited |
| Device Type: |
Battery String Monitor |
| Family: |
PowerShield8 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| PowerShield Controller LX |
| PowerShield Controller MX |
Additional Information:
Reference Documents:
| Document: |
PS-B1002-MIB |
| Version: |
201706210000Z |
| Sections: |
1.3.6.1.4.1.35154.1002.* |
| URL: |
Not Available
|
Proges Plus EMS Sensor Net Connect
| Manufacturer: |
Proges Plus |
| Device Type: |
EMS |
| Family: |
Sensor Net Connect |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
EDS_MIB_V2.1.mib |
| Version: |
2.1 |
| Sections: |
edsEnterprise (.1.3.6.1.4.1.31440.1.*)
owDeviceTable (.1.3.6.1.4.1.31440.10.3.*)
owEDS0065Table (.1.3.6.1.4.1.31440.10.12.*)
owEDS0001Table (.1.3.6.1.4.1.31440.10.28.*)
|
| URL: |
Not Available
|
Qualitrol Company LLC Intelligent Transformer Monitor 118 ITM
| Manufacturer: |
Qualitrol Company LLC |
| Device Type: |
Intelligent Transformer Monitor |
| Family: |
118 ITM |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
RC Group CRAC Next EVO
| Manufacturer: |
RC Group |
| Device Type: |
CRAC |
| Family: |
Next EVO |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Application BAC - Supervisor parameters table RC Group S.p.A. |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
RLE Technologies EMS Wing
| Manufacturer: |
RLE Technologies |
| Device Type: |
EMS |
| Family: |
Wing |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
wing-mgr.mib |
| Version: |
1.0.4 |
| Sections: |
wingMgrIdent (.1.3.6.1.4.1.3184.1.15.1.*)
wingMgrSensors (.1.3.6.1.4.1.3184.1.15.2.*)
|
| URL: |
Not Available
|
| Document: |
WiNGSensorDataReferenceGuide-05-21.pdf |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
Raritan Rack PDU RaritanPXPdu
| Manufacturer: |
Raritan |
| Device Type: |
Rack PDU |
| Family: |
RaritanPXPdu |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Raritan Dominion PX |
| Firmware Versions: |
| 01.05.05-10603 |
Additional Information:
Reference Documents:
| Document: |
MIB_PX3270 |
| Version: |
Not Available
|
| Sections: |
|
| URL: |
Not Available
|
Raritan Inc. Rack PDU PX2/PX3
| Manufacturer: |
Raritan Inc. |
| Device Type: |
Rack PDU |
| Family: |
PX2/PX3 |
| Protocol: |
SNMP |
Models Tested:
| PX2-1486 |
| PX2-1551 |
| PX2-1724 |
| PX2-1971I2U-E2V2A7 |
| PX2-2145R |
| PX2-3123 |
| PX2-4397 |
| PX2-4523T-N3K701 |
| PX2-4551-E2N1V2K9 |
| PX2-4724-E2N1K9 |
| PX2-5493-K1 |
| PX2-5530 |
| PX2-5701 |
| PX2-5732-F5 |
| PX3-5041V-F5M5 |
| PX3-5145R |
| PX3-5730V-K1 |
Network Cards:
| Raritan iX7 Intelligent Field Replaceable Controller |
| Firmware Versions: |
| 2.3.1.5-37516 |
| 2.3.7.5-39116 |
| 2.4.1.5-39763 |
| 2.4.3.5-40298 |
| 3.0.1.5-41478 |
| 3.0.4.5-41800 |
| 3.1.0.5-42165 |
| 3.4.0.5-44367 |
| 3.5.0.5-45371 |
Additional Information:
|
2000-series and 5000-series RPDUs have switchable outlets.
4000-series and 5000-series RPDUs have per-Outlet metering.
1000-series RPDUs have neither of these.
|
Reference Documents:
Redetec Limited Fire Suppression System PN/Red/3.0/FAL
| Manufacturer: |
Redetec Limited |
| Device Type: |
Fire Suppression System |
| Family: |
PN/Red/3.0/FAL |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Register Map Generated From Device |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
Redetec Limited Fire Suppression System PN/Red/3.0
| Manufacturer: |
Redetec Limited |
| Device Type: |
Fire Suppression System |
| Family: |
PN/Red/3.0 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
XYTRONIX-MIB |
| Version: |
Not Available
|
| Sections: |
1.3.6.1.4.1.30586.21.* |
| URL: |
Not Available
|
Redetec Limited Fire Suppression System PN/Red/3.0/FAL
| Manufacturer: |
Redetec Limited |
| Device Type: |
Fire Suppression System |
| Family: |
PN/Red/3.0/FAL |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
XYTRONIX-MIB |
| Version: |
Not Available
|
| Sections: |
1.3.6.1.4.1.30586.54.* |
| URL: |
Not Available
|
Riello ATS NetMan 204
| Manufacturer: |
Riello |
| Device Type: |
ATS |
| Family: |
NetMan 204 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Riello STS NetMan 204
| Manufacturer: |
Riello |
| Device Type: |
STS |
| Family: |
NetMan 204 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Riello UPS NetMan 204
| Manufacturer: |
Riello |
| Device Type: |
UPS |
| Family: |
NetMan 204 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Rittal Chiller LCP
| Manufacturer: |
Rittal |
| Device Type: |
Chiller |
| Family: |
LCP |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
CAREL-ug40cdz-MIB |
| Version: |
200604111645Z |
| Sections: |
digitalObjects (.1.3.6.1.4.1.9839.2.1.1)
analogObjects (.1.3.6.1.4.1.9839.2.1.2)
integerObjects (.1.3.6.1.4.1.9839.2.1.3)
|
| URL: |
Not Available
|
Rittal Chiller Kelvin
| Manufacturer: |
Rittal |
| Device Type: |
Chiller |
| Family: |
Kelvin |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
snmp_mibs_RITTAL-pCOWeb-Chiller-MIB.mib |
| Version: |
201309131602Z |
| Sections: |
digitalObjects (.1.3.6.1.4.1.2606.20.2.1.1)
analogObjects (.1.3.6.1.4.1.2606.20.2.1.2)
integerObjects (.1.3.6.1.4.1.2606.20.2.1.3)
|
| URL: |
Not Available
|
Rittal Chiller RiMatrix-S
| Manufacturer: |
Rittal |
| Device Type: |
Chiller |
| Family: |
RiMatrix-S |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
pCOWeb_NEWChillerIT_RimatriX_2014.mib |
| Version: |
200604111645Z |
| Sections: |
digitalObjects (.1.3.6.1.4.1.9839.2.1.1)
analogObjects (.1.3.6.1.4.1.9839.2.1.2)
integerObjects (.1.3.6.1.4.1.9839.2.1.3)
|
| URL: |
Not Available
|
Rittal PDU Smart PDU
| Manufacturer: |
Rittal |
| Device Type: |
PDU |
| Family: |
Smart PDU |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
Additional Information:
| Created based on list of connected devices via DCE. Cannot find much information on
this device. |
Reference Documents:
| Document: |
ED-3S625A-DE32PV.MIB |
| Version: |
Not Available
|
| Sections: |
sPDU (1.3.6.1.4.1.40367.1.1.12.*)
|
| URL: |
Not Available
|
Rittal GmbH & Co. KG Monitoring System Computer Multi-Control III
| Manufacturer: |
Rittal GmbH & Co. KG |
| Device Type: |
Monitoring System |
| Family: |
Computer Multi-Control III |
| Protocol: |
SNMP |
Models Tested:
| 3311.230 - Liquid Cooling Package |
| 3312.230 - Liquid Cooling Package |
| 7030.000 - Processing Unit |
| 7030.040 - I/O Input |
| 7030.110 - Temperature Probe |
| 7030.111 - Temp/Humidity Probe |
| 7030.430/440 - Leak Sensor |
| 7338.121 - DET-AC III Master Fire Alarm/Extinguisher |
| 7998.106 - RiMatrix S S6W |
Network Cards:
| CMC III Processing Unit |
| Firmware Versions: |
| V3.15.70_4 |
| V3.17.10 |
| V5.15.40_2 |
Additional Information:
Reference Documents:
Rittal GmbH & Co. KG Monitoring System Computer Multi-Control TC
| Manufacturer: |
Rittal GmbH & Co. KG |
| Device Type: |
Monitoring System |
| Family: |
Computer Multi-Control TC |
| Protocol: |
SNMP |
Models Tested:
| Temperature Sensor (I/O) |
| Humidity Sensor (I/O) |
| LCP-R 30kW |
| LCP Plus EC |
| Metered Power System Module (PSM) |
Network Cards:
| CMC TC Processing Unit |
| Firmware Versions: |
| V2.90.04 |
| V6.54.00 |
Additional Information:
Reference Documents:
| Document: |
CMC-TC-MIB |
| Version: |
1.2a, 2009-03-05 |
| Sections: |
.1.3.6.1.4.1.2606.4.* |
| URL: |
Not Available
|
Rolls Royce Generator MTU
| Manufacturer: |
Rolls Royce |
| Device Type: |
Generator |
| Family: |
MTU |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
12620101EN - KS-VISION - Modbus supervision protocol_rev12.pdf |
| Version: |
Revision 12 |
| Sections: |
Data address inside the PLC |
| URL: |
Not Available
|
S&P Generic Heat Recover Unit
| Manufacturer: |
S&P |
| Device Type: |
Generic |
| Family: |
Heat Recover Unit |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Ins_MODBUS_DOMEO_2v_EN |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
SICES Generator GC3xx
| Manufacturer: |
SICES |
| Device Type: |
Generator |
| Family: |
GC3xx |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
141175-LIST-MODB-VERS-20140706 |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
Schleifenbauer RPDU HPDU
| Manufacturer: |
Schleifenbauer |
| Device Type: |
RPDU |
| Family: |
HPDU |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Server Technology Inc. (ServerTech) RPDU Sentry4
| Manufacturer: |
Server Technology Inc. (ServerTech) |
| Device Type: |
RPDU |
| Family: |
Sentry4 |
| Protocol: |
SNMP |
Models Tested:
| CW-16H2C452 |
| CW-16HEK454 |
| CWG-24V4K458A9 |
| CX-16H2C452 |
| STV-4102C/C |
Network Cards:
| Network Management Module |
| Firmware Versions: |
| 7.0k |
| 7.0p |
| 7.0t |
Additional Information:
Reference Documents:
| Document: |
Sentry3.mib |
| Version: |
201406251200Z |
| Sections: |
systemGroup (.1.3.6.1.4.1.1718.3.1.*)
towerTable (.1.3.6.1.4.1.1718.3.2.1.*)
infeedTable (.1.3.6.1.4.1.1718.3.2.2.*)
outletTable (.1.3.6.1.4.1.1718.3.2.3.*)
envMonTable (.1.3.6.1.4.1.1718.3.2.4.*)
tempHumidSensorTable (.1.3.6.1.4.1.1718.3.2.5.*)
contactClosureTable (.1.3.6.1.4.1.1718.3.2.6.*)
|
| URL: |
https://www.servertech.com/support/sentry-mib-oid-tree-downloads/
|
Server Technology Inc. (ServerTech) RPDU Sentry4
| Manufacturer: |
Server Technology Inc. (ServerTech) |
| Device Type: |
RPDU |
| Family: |
Sentry4 |
| Protocol: |
SNMP |
Models Tested:
| C2W36CE-DCMFAM00 |
| C2S36CE-YQME2M66/C |
| C2WG36CE-2CAF2M63 |
Network Cards:
| Smart PRO2 |
| Firmware Versions: |
| 8.0b |
| 8.0k |
| 8.0n |
Additional Information:
Reference Documents:
| Document: |
Sentry4.mib |
| Version: |
202007021900Z |
| Sections: |
st4Units (.1.3.6.1.4.1.1718.4.1.2.*)
st4InputCords (.1.3.6.1.4.1.1718.4.1.3.*)
st4Lines (.1.3.6.1.4.1.1718.4.1.4.*)
st4Phases (.1.3.6.1.4.1.1718.4.1.5.*)
st4OverCurrentProtectors (.1.3.6.1.4.1.1718.4.1.6.*)
st4Branches (.1.3.6.1.4.1.1718.4.1.7.*)
st4Outlets (.1.3.6.1.4.1.1718.4.1.8.*)
st4TemperatureSensors (.1.3.6.1.4.1.1718.4.1.9.*)
st4HumiditySensors (.1.3.6.1.4.1.1718.4.1.10.*)
st4WaterSensors (.1.3.6.1.4.1.1718.4.1.11.*)
st4ContactClosureSensors (.1.3.6.1.4.1.1718.4.1.12.*)
st4AnalogToDigitalConvSensors (.1.3.6.1.4.1.1718.4.1.13.*)
st4FanSensors (.1.3.6.1.4.1.1718.4.1.14.*)
|
| URL: |
https://www.servertech.com/support/sentry-mib-oid-tree-downloads/
|
Sesnatronics EMS Model U
| Manufacturer: |
Sesnatronics |
| Device Type: |
EMS |
| Family: |
Model U |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
SENSATRONICS-SMI |
| Version: |
200404200000Z |
| Sections: |
envMonitors (.1.3.6.1.4.1.16174.1.1.*) |
| URL: |
Not Available
|
| Document: |
SENSATRONICS-ITMU |
| Version: |
200802230900Z |
| Sections: |
productITMU (.1.3.6.1.4.1.16174.1.1.4.*) |
| URL: |
Not Available
|
Siemens AG Power Meter SENTRON PAC3200 Power Monitoring Device
| Manufacturer: |
Siemens AG |
| Device Type: |
Power Meter |
| Family: |
SENTRON PAC3200 Power Monitoring Device |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Siemens SENTRON, Power Monitoring Device SENTRON PAC3200, Manual |
| Version: |
Feb 2008, A5E01168664B-04 |
| Sections: |
Tables 3-6, 3-10, 3-11, 3-12, 3-13, 3-14, 3-15, 3-16, 3-17, 3-18, 3-19, 3-20, 3-21
(pgs.40-57) |
| URL: |
https://support.industry.siemens.com/cs/attachments/26504150/A5E01168664B-04_EN-US_122016_201612221316360495.pdf
|
Sinetica Unit Controller Hawk i2
| Manufacturer: |
Sinetica |
| Device Type: |
Unit Controller |
| Family: |
Hawk i2 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Socomec Power Meter DIRIS Digiware M and D
| Manufacturer: |
Socomec |
| Device Type: |
Power Meter |
| Family: |
DIRIS Digiware M and D |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
| Firmware Versions: |
| 2.2.8.2 |
Additional Information:
Reference Documents:
Socomec Static Transfer Switch STATYS XS
| Manufacturer: |
Socomec |
| Device Type: |
Static Transfer Switch |
| Family: |
STATYS XS |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| STATYS XS |
| Firmware Versions: |
| ATS2186D |
Additional Information:
Reference Documents:
| Document: |
ATS-MIB |
| Version: |
Not Available
|
| Sections: |
|
| URL: |
Not Available
|
Socomec UPS Delphys Green Power
| Manufacturer: |
Socomec |
| Device Type: |
UPS |
| Family: |
Delphys Green Power |
| Protocol: |
SNMP |
Models Tested:
| LCCH-6SVR-UPSA |
| LCCH-B2COMSB-UPSA |
Network Cards:
Additional Information:
Reference Documents:
| Document: |
UPS_Adicom_MIB_104-win.mib |
| Version: |
1.04 |
| Sections: |
Not Available
|
| URL: |
Not Available
|
Socomec UPS Net Vision 6
| Manufacturer: |
Socomec |
| Device Type: |
UPS |
| Family: |
Net Vision 6 |
| Protocol: |
SNMP |
Models Tested:
| DELPHYS MP PARALLEL 80 kVA |
| ITYS 6 kVA |
| MASTERYS 3/3 SYSTEM 60 kVA |
| THREE/THREE UPS 160 kVA |
Network Cards:
| Net Vision 6 |
| Firmware Versions: |
| 6.01 |
| 6.21 |
| 6.32 |
Additional Information:
Reference Documents:
| Document: |
NetVision-nv620-win.mib |
| Version: |
6.20 |
| Sections: |
upsIdent (.1.3.6.1.4.1.4555.1.1.1.1.1.*)
upsBattery (.1.3.6.1.4.1.4555.1.1.1.2.1.*)
upsInput (.1.3.6.1.4.1.4555.1.1.1.1.3.*)
upsOutput (.1.3.6.1.4.1.4555.1.1.1.1.4.*)
upsBypass (.1.3.6.1.4.1.4555.1.1.1.1.5.*)
upsAlarm (.1.3.6.1.4.1.4555.1.1.1.1.6.*)
emdStatus (.1.3.6.1.4.1.4555.1.1.1.1.11.*)
|
| URL: |
|
Socomec UPS Net Vision 7
| Manufacturer: |
Socomec |
| Device Type: |
UPS |
| Family: |
Net Vision 7 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
NetVision-7_1_2.mib |
| Version: |
7.12 |
| Sections: |
upsIdent (.1.3.6.1.4.1.4555.1.1.7.1.1.*)
upsBattery (.1.3.6.1.4.1.4555.1.1.7.2.1.*)
upsInput (.1.3.6.1.4.1.4555.1.1.7.1.3.*)
upsOutput (.1.3.6.1.4.1.4555.1.1.7.1.4.*)
upsBypass (.1.3.6.1.4.1.4555.1.1.7.1.5.*)
upsAlarm (.1.3.6.1.4.1.4555.1.1.7.1.6.*)
|
| URL: |
https://www.socomec.com/net-vision-7-software_en.html
|
Socomec Inc. Power Meter Diris A10 Modular Power Metering and Monitoring Device
| Manufacturer: |
Socomec Inc. |
| Device Type: |
Power Meter |
| Family: |
Diris A10 Modular Power Metering and Monitoring Device |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Socomec Inc. Power Meter Diris A20 Modular Power Metering and Monitoring Device
| Manufacturer: |
Socomec Inc. |
| Device Type: |
Power Meter |
| Family: |
Diris A20 Modular Power Metering and Monitoring Device |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Socomec Inc. Power Meter Diris A40/A41 Multifunction Meter
| Manufacturer: |
Socomec Inc. |
| Device Type: |
Power Meter |
| Family: |
Diris A40/A41 Multifunction Meter |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Socomec Inc. Power Meter Diris A60 Multifunction Meter
| Manufacturer: |
Socomec Inc. |
| Device Type: |
Power Meter |
| Family: |
Diris A60 Multifunction Meter |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Socomec Inc. Power Meter Diris A80 Multifunction Meter
| Manufacturer: |
Socomec Inc. |
| Device Type: |
Power Meter |
| Family: |
Diris A80 Multifunction Meter |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Stulz Crac CyberAir 3PRO
| Manufacturer: |
Stulz |
| Device Type: |
Crac |
| Family: |
CyberAir 3PRO |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
STULZ_udpl_421_modbus.pdf |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
Stulz Crac SplitAir3
| Manufacturer: |
Stulz |
| Device Type: |
Crac |
| Family: |
SplitAir3 |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
STULTZ Data Point List Secblue.pdf |
| Version: |
5 |
| Sections: |
Not Available
|
| URL: |
Not Available
|
Stulz CRAC Wall Air
| Manufacturer: |
Stulz |
| Device Type: |
CRAC |
| Family: |
Wall Air |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
STULZ-TM172SIP-MIB.mib |
| Version: |
202303141252Z |
| Sections: |
Not Available
|
| URL: |
Not Available
|
Stulz EMS WIB 8000
| Manufacturer: |
Stulz |
| Device Type: |
EMS |
| Family: |
WIB 8000 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| WIB 8000 |
| Firmware Versions: |
| 1.25 |
| 1.32 |
| 1.35 |
| 1.37 |
| 1.40 |
| 1.42 |
| 2.05 |
Additional Information:
Reference Documents:
| Document: |
StulzWIB8000_v152.mib |
| Version: |
v152 |
| Sections: |
infoValTemperatureTable:
unitAirTemperature (.1.3.6.1.4.1.29462.10.2.1.1.1.1.1.1.1.1170.*)
unitEmergencyTemperature (.1.3.6.1.4.1.29462.10.2.1.1.1.1.1.1.1.1172.*)
unitReturnAirTemperature (.1.3.6.1.4.1.29462.10.2.1.1.1.1.1.1.1.1192.*)
unitSupplyAirTemperature (.1.3.6.1.4.1.29462.10.2.1.1.1.1.1.1.1.1193.*)
unitOutsideAirTemperature (.1.3.6.1.4.1.29462.10.2.1.1.1.1.1.1.1.1196.*)
unitOutsideAirHumidity (.1.3.6.1.4.1.29462.10.2.1.1.1.1.1.1.1.1197.*)
infoValHumidityTable:
unitHumidity (.1.3.6.1.4.1.29462.10.2.1.1.1.1.2.1.1.1171.*)
unitReturnAirHumidity (.1.3.6.1.4.1.29462.10.2.1.1.1.1.2.1.1.1194.*)
unitSupplyAirHumidity (.1.3.6.1.4.1.29462.10.2.1.1.1.1.2.1.1.1195.*)
infoValPressureTable:
currentRaisedFloorPressure (.1.3.6.1.4.1.29462.10.2.1.1.1.1.3.1.1.1208.*)
infoValWaterTable:
waterInTemperatu1ChillersPrimary (.1.3.6.1.4.1.29462.10.2.1.1.1.2.1.1.1191.*)
waterInTemperatuhillersSecondary (.1.3.6.1.4.1.29462.10.2.1.1.1.2.1.1.1202.*)
waterOutTemperatChillersPrimary (.1.3.6.1.4.1.29462.10.2.1.1.1.2.1.1.1206.*)
waterOutTemperatillersSecondary (.1.3.6.1.4.1.29462.10.2.1.1.1.2.1.1.1207.*)
unitSetpointWaterPressure (.1.3.6.1.4.1.29462.10.2.1.1.1.2.1.1.1211.*)
waterTemperaturetpointCorrected (.1.3.6.1.4.1.29462.10.2.1.1.1.2.1.1.1240.*)
infoValRefrigerantTable:
unitSuctionGasTemperature1 (.1.3.6.1.4.1.29462.10.2.1.1.1.3.1.1.2232.*)
unitEvaporationPressure1 (.1.3.6.1.4.1.29462.10.2.1.1.1.3.1.1.2233.*)
unitCondensationPressure1 (.1.3.6.1.4.1.29462.10.2.1.1.1.3.1.1.2235.*)
unitSuctionPressure1 (.1.3.6.1.4.1.29462.10.2.1.1.1.3.1.1.2278.*)
unitSuctionPressure2 (.1.3.6.1.4.1.29462.10.2.1.1.1.3.1.1.2279.*)
runningHoursFliter (.1.3.6.1.4.1.29462.10.2.1.1.1.3.1.1.10291.*)
infoValAEcontrolTable:
operationMode (.1.3.6.1.4.1.29462.10.2.1.1.1.4.1.1.10315.*)
infoValMiscellaneous:
electricCabinetTemp (.1.3.6.1.4.1.29462.10.2.1.1.1.5.1.1.1283.*)
intermediateTempMixTemp (.1.3.6.1.4.1.29462.10.2.1.1.1.5.1.1.1284.*)
coldWaterRequest (.1.3.6.1.4.1.29462.10.2.1.1.1.5.1.1.1778.*)
freezeCirculationRunning (.1.3.6.1.4.1.29462.10.2.1.1.1.5.1.1.1780.*)
infoValuesControlTable:
bMSStop2 (.1.3.6.1.4.1.29462.10.2.1.1.1.6.1.1.1783.*)
condensationPressureDynamic1 (.1.3.6.1.4.1.29462.10.2.1.1.1.6.1.1.1784.*)
condensationPressureDynamic2 (.1.3.6.1.4.1.29462.10.2.1.1.1.6.1.1.1785.*)
condensationPresmic1SetpointEp1 (.1.3.6.1.4.1.29462.10.2.1.1.1.6.1.1.1791.*)
condensationPresmic1SetpointCp1 (.1.3.6.1.4.1.29462.10.2.1.1.1.6.1.1.1792.*)
condensationPresmic1SetpointEp2 (.1.3.6.1.4.1.29462.10.2.1.1.1.6.1.1.1793.*)
condensationPresmic1SetpointCp2 (.1.3.6.1.4.1.29462.10.2.1.1.1.6.1.1.1794.*)
condensationPresmic2SetpointEp1 (.1.3.6.1.4.1.29462.10.2.1.1.1.6.1.1.1795.*)
condensationPresmic2SetpointCp1 (.1.3.6.1.4.1.29462.10.2.1.1.1.6.1.1.1796.*)
condensationPresmic2SetpointEp2 (.1.3.6.1.4.1.29462.10.2.1.1.1.6.1.1.1797.*)
condensationPresmic2SetpointCp2 (.1.3.6.1.4.1.29462.10.2.1.1.1.6.1.1.1798.*)
infoModulefunctionsComponents:
numberOfCompressors (.1.3.6.1.4.1.29462.10.2.1.1.2.1.1.1.1.1761.*)
numberOfSuctionValves (.1.3.6.1.4.1.29462.10.2.1.1.2.1.1.1.1.1762.*)
numberOfGeCWValves (.1.3.6.1.4.1.29462.10.2.1.1.2.1.2.1.1.1771.*)
numberOfEEVs (.1.3.6.1.4.1.29462.10.2.1.1.2.1.2.5.1.1776.*)
numberOfHotgasBypass (.1.3.6.1.4.1.29462.10.2.1.1.2.1.2.5.1.1786.*)
numberGValves (.1.3.6.1.4.1.29462.10.2.1.1.2.1.2.5.1.1788.*)
numberOfCondenserFans (.1.3.6.1.4.1.29462.10.2.1.1.2.1.2.5.1.1789.*)
freecoolingPossible (.1.3.6.1.4.1.29462.10.2.1.1.2.1.2.5.1.10101.*)
numberOfDrycoolers (.1.3.6.1.4.1.29462.10.2.1.1.2.1.3.1.1.1763.*)
numberOfPumps (.1.3.6.1.4.1.29462.10.2.1.1.2.1.4.1.1.1764.*)
numberOfHotgasReheat (.1.3.6.1.4.1.29462.10.2.1.1.2.4.1.1.1772.*)
numberOfPwwHeatings (.1.3.6.1.4.1.29462.10.2.1.1.2.4.1.1.1773.*)
numberOfDehumidifiers (.1.3.6.1.4.1.29462.10.2.1.1.2.4.1.1.1774.*)
infoStatRuntimesTable:
unitRuntimeCooling (.1.3.6.1.4.1.29462.10.2.1.1.4.4.1.1.1.1166.*)
unitRuntimeHeating (.1.3.6.1.4.1.29462.10.2.1.1.4.4.1.1.1.1167.*)
unitRuntimeHumidification (.1.3.6.1.4.1.29462.10.2.1.1.4.4.1.1.1.1168.*)
unitRuntimeDehumidification (.1.3.6.1.4.1.29462.10.2.1.1.4.4.1.1.1.1169.*)
unitRuntimeFreecooling (.1.3.6.1.4.1.29462.10.2.1.1.4.4.1.1.1.1203.*)
unitRuntimeFreecoolMixmode (.1.3.6.1.4.1.29462.10.2.1.1.4.4.1.1.1.1204.*)
unitRuntimeUnit (.1.3.6.1.4.1.29462.10.2.1.1.4.4.3.1.1164.*)
unitStoptimeUnit (.1.3.6.1.4.1.29462.10.2.1.1.4.4.3.1.1165.*)
|
| URL: |
Not Available
|
Synaccess Networks Inc. RPDU SYNLINK RPDU
| Manufacturer: |
Synaccess Networks Inc. |
| Device Type: |
RPDU |
| Family: |
SYNLINK RPDU |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Toshiba International Corp UPS RemotEye III-based
| Manufacturer: |
Toshiba International Corp |
| Device Type: |
UPS |
| Family: |
RemotEye III-based |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Toshiba RemotEye III |
| Firmware Versions: |
| UH3MSV01050 |
Additional Information:
Reference Documents:
Toshiba International Corp UPS RemotEye 4-based 1600XP UPS
| Manufacturer: |
Toshiba International Corp |
| Device Type: |
UPS |
| Family: |
RemotEye 4-based 1600XP UPS |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Toshiba RemotEye 4 |
| Firmware Versions: |
| main firmware version: UH3MSV01050, boot sector version: UH3MBS01000, boot loader
version: UH3MBL01000, EEPROM version: UH3MEE01050 |
Additional Information:
| for devices with upsIdentTypeform (1.3.6.1.4.1.186.1.19.2.5.2.1.2) starting with "UH3G2L","H3BE1E","H3BG2L" |
Reference Documents:
Toshiba International Corp UPS RemotEye 4-based G9000 UPS
| Manufacturer: |
Toshiba International Corp |
| Device Type: |
UPS |
| Family: |
RemotEye 4-based G9000 UPS |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Toshiba RemotEye 4 |
| Firmware Versions: |
| RK8FD0_T4.ldRFGXA0.hex JEA1490A |
Additional Information:
| for devices with upsIdentTypeform (1.3.6.1.4.1.186.1.19.2.5.8.1.2) starting with "T901H","T90N3P","T90S3S" |
Reference Documents:
Toshiba International Corp UPS RemotEye II-based
| Manufacturer: |
Toshiba International Corp |
| Device Type: |
UPS |
| Family: |
RemotEye II-based |
| Protocol: |
SNMP |
Models Tested:
| 1000-series |
| G8000MM |
| G9000 |
Network Cards:
| Toshiba RemotEye II |
| Firmware Versions: |
| Main v1.0, Interface v1.0 |
| RK8FD0_T4.ldRFGXA0.hex JEA1490A |
Additional Information:
Reference Documents:
TrendPoint BCM EnerSure
| Manufacturer: |
TrendPoint |
| Device Type: |
BCM |
| Family: |
EnerSure |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
| Firmware Versions: |
| 3800 |
| 4900 |
Additional Information:
Reference Documents:
| Document: |
TRENDPOINT-ENERSURE-MIB |
| Version: |
201010260000Z |
| Sections: |
tpEsStack (.1.3.6.1.4.1.10381.1.3.1.1)
tpEsCircuits (.1.3.6.1.4.1.10381.1.3.1.3)
|
| URL: |
Not Available
|
Tripp Lite ATS WEBCARDLX
| Manufacturer: |
Tripp Lite |
| Device Type: |
ATS |
| Family: |
WEBCARDLX |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| WEBCARDLX |
| Firmware Versions: |
| 6924150A |
Additional Information:
Reference Documents:
| Document: |
TRIPPLITE-PRODUCTS.mib |
| Version: |
202012160000Z |
| Sections: |
tlpAtsIdent (.1.3.6.1.4.1.850.1.1.3.4.1.*)
tlpAtsDevice (.1.3.6.1.4.1.850.1.1.3.4.2.*)
tlpAtsInput (.1.3.6.1.4.1.850.1.1.3.4.3.1.*)
tlpAtsOutput (.1.3.6.1.4.1.850.1.1.3.4.3.2.*)
tlpAtsOutlet (.1.3.6.1.4.1.850.1.1.3.4.3.3.*)
|
| URL: |
https://www.tripplite.com/products/management-firmware-matrix
|
Tripp Lite CRAC WEBCARDLX
| Manufacturer: |
Tripp Lite |
| Device Type: |
CRAC |
| Family: |
WEBCARDLX |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
TRIPPLITE-PRODUCTS |
| Version: |
202110130000Z |
| Sections: |
tlpCoolingIdent (.1.3.6.1.4.1.850.1.1.3.5.1.*)
tlpCoolingDevice (.1.3.6.1.4.1.850.1.1.3.5.2.*)
tlpCoolingDetail (.1.3.6.1.4.1.850.1.1.3.5.3.*)
tlpCoolingConfig (.1.3.6.1.4.1.850.1.1.3.5.5.*)
tlpAlarms (.1.3.6.1.4.1.850.1.3.*)
|
| URL: |
https://www.tripplite.com/products/management-firmware-matrix
|
Tripp Lite RPDU WEBCARDLX
| Manufacturer: |
Tripp Lite |
| Device Type: |
RPDU |
| Family: |
WEBCARDLX |
| Protocol: |
SNMP |
Models Tested:
| PDUMH15NET |
| PDUMVR30HVNETLX |
Network Cards:
| WEBCARDLX |
| Firmware Versions: |
| 6926600B |
| 693038B |
Additional Information:
Reference Documents:
| Document: |
TRIPPLITE-PRODUCTS.mib |
| Version: |
202012160000Z |
| Sections: |
tlpPduIdent (.1.3.6.1.4.1.850.1.1.3.2.1.*)
tlpPduDevice (.1.3.6.1.4.1.850.1.1.3.2.2.*)
tlpPduInput (.1.3.6.1.4.1.850.1.1.3.2.3.1.*)
tlpPduOutput (.1.3.6.1.4.1.850.1.1.3.2.3.2.*)
tlpPduOutlet (.1.3.6.1.4.1.850.1.1.3.2.3.3.*)
tlpPduCircuit (.1.3.6.1.4.1.850.1.1.3.2.3.4.*)
tlpPduBreaker (.1.3.6.1.4.1.850.1.1.3.2.3.5.*)
tlpEnvTemperatureTable (.1.3.6.1.4.1.850.1.1.3.3.3.1.*)
tlpEnvHumidityTable (.1.3.6.1.4.1.850.1.1.3.3.3.2.*)
tlpEnvInputContactTable (.1.3.6.1.4.1.850.1.1.3.3.3.3.*)
tlpEnvOutputContactTable (.1.3.6.1.4.1.850.1.1.3.3.3.4.*)
|
| URL: |
https://www.tripplite.com/products/management-firmware-matrix
|
Tripp Lite RPDU SNMPWEBCARD
| Manufacturer: |
Tripp Lite |
| Device Type: |
RPDU |
| Family: |
SNMPWEBCARD |
| Protocol: |
SNMP |
Models Tested:
| PDU3VSR6L1530 |
| PDUMH20AT |
| PDUMH20ATNET |
| PDUMV30HVNET |
Network Cards:
| SNMPWEBCARD |
| Firmware Versions: |
| 6926680B |
| 6929220B |
| 6929890B |
Additional Information:
Reference Documents:
Tripp Lite UPS WEBCARDLX
| Manufacturer: |
Tripp Lite |
| Device Type: |
UPS |
| Family: |
WEBCARDLX |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
TRIPPLITE-PRODUCTS.mib |
| Version: |
202012160000Z |
| Sections: |
tlpUpsIdent (.1.3.6.1.4.1.850.1.1.3.1.1.*)
tlpUpsDevice (.1.3.6.1.4.1.850.1.1.3.1.2.*)
tlpUpsInput (.1.3.6.1.4.1.850.1.1.3.1.3.2.*)
tlpUpsOutput (.1.3.6.1.4.1.850.1.1.3.1.3.3.*)
tlpUpsBypass (.1.3.6.1.4.1.850.1.1.3.1.3.4.*)
tlpUpsOutlet (.1.3.6.1.4.1.850.1.1.3.1.3.5.*)
|
| URL: |
https://www.tripplite.com/products/management-firmware-matrix
|
Tripp Lite UPS SNMPWEBCARD
| Manufacturer: |
Tripp Lite |
| Device Type: |
UPS |
| Family: |
SNMPWEBCARD |
| Protocol: |
SNMP |
Models Tested:
| SMART750RM1U |
| SMART1000RM1U |
| SU1500RTXL2Ua |
| SU10000RT3UPM |
Network Cards:
| SNMPWEBCARD |
| Firmware Versions: |
| 08 |
| 19 |
| 1218 (Rev A) |
| 2264 (Rev A) |
Additional Information:
Reference Documents:
Uptime Devices EMS Sensor Hub
| Manufacturer: |
Uptime Devices |
| Device Type: |
EMS |
| Family: |
Sensor Hub |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
uptimedevices_shpro_mib.mib |
| Version: |
v 1.7 - 2004/05/05 |
| Sections: |
1.3.6.1.4.1.13045.1.2.* |
| URL: |
Not Available
|
Various UPS RFC1628-compliant UPS
| Manufacturer: |
Various |
| Device Type: |
UPS |
| Family: |
RFC1628-compliant UPS |
| Protocol: |
SNMP |
Models Tested:
| Chloride 80Net |
| CPS OL2000ERTXL2U |
| Delta GES602R2120B0 |
| HP RT3000 G2 UPS |
| TrippLite SU1500RTXLCD2U |
| TrippLite SU2200RTXLCD2U |
Network Cards:
Additional Information:
|
Devices adhering to the standard set forth in the IETF's document RFC 1628,
which defines a standard set of measurement, setting, and alarm data points
for Uninterruptible Power Supply (UPS) systems.
|
Reference Documents:
Vertiv CRAC EEV
| Manufacturer: |
Vertiv |
| Device Type: |
CRAC |
| Family: |
EEV |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 6.5.0.0 |
Additional Information:
Reference Documents:
| Document: |
LIEBERT-GP-ENVIRONMENTAL-MIB |
| Version: |
v.18, Tue Jul 28 21:49:40 EDT 2020 |
| Sections: |
1.3.6.1.4.1.476.1.42.3.4.* |
| URL: |
Not Available
|
Vertiv System Level Controller NetSure
| Manufacturer: |
Vertiv |
| Device Type: |
System Level Controller |
| Family: |
NetSure |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| NCU |
| Firmware Versions: |
| 5.2.0301 |
Additional Information:
Reference Documents:
| Document: |
NETSURE-NCU-MIB |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
| Document: |
EES-POWER-MIB |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
Vertiv / Emerson Network Power UPS NXR
| Manufacturer: |
Vertiv / Emerson Network Power |
| Device Type: |
UPS |
| Family: |
NXR |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
nxr.mib |
| Version: |
200902011512Z |
| Sections: |
.1.3.6.1.4.1.13400.2.19.* |
| URL: |
Not Available
|
Vertiv / Emerson Network Power UPS NXC
| Manufacturer: |
Vertiv / Emerson Network Power |
| Device Type: |
UPS |
| Family: |
NXC |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
nxc3040k.mib |
| Version: |
200911231030Z |
| Sections: |
.1.3.6.1.4.1.13400.2.43.* |
| URL: |
Not Available
|
Vertiv / Emerson Network Power UPS GXT3
| Manufacturer: |
Vertiv / Emerson Network Power |
| Device Type: |
UPS |
| Family: |
GXT3 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
GXT3G.mib |
| Version: |
200902011512Z |
| Sections: |
.1.3.6.1.4.1.13400.2.71.* |
| URL: |
Not Available
|
Vertiv / Emerson Network Power UPS GXT4
| Manufacturer: |
Vertiv / Emerson Network Power |
| Device Type: |
UPS |
| Family: |
GXT4 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
ENP UPS GXT4G.mib |
| Version: |
revision 200, 201309020955Z |
| Sections: |
.1.3.6.1.4.1.13400.2.439.* |
| URL: |
Not Available
|
Vertiv / Geist Environmental Monitor Geist Blackbird series
| Manufacturer: |
Vertiv / Geist |
| Device Type: |
Environmental Monitor |
| Family: |
Geist Blackbird series |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
GEIST-V4-MIB |
| Version: |
201209110000Z |
| Sections: |
1.3.6.1.4.1.21239.5.1.* |
| URL: |
Not Available
|
Vertiv / Liebert Branch Circuit Monitor LDMF Controller
| Manufacturer: |
Vertiv / Liebert |
| Device Type: |
Branch Circuit Monitor |
| Family: |
LDMF Controller |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Liebert(R) IntelliSlot(TM) Modbus and BACnet Protocols, Reference Guide |
| Version: |
Not Available
|
| Sections: |
Tables 3.46-3.47 (pgs.374-386) |
| URL: |
Not Available
|
Vertiv / Liebert CRAC Liebert iCOM v4 Controller
| Manufacturer: |
Vertiv / Liebert |
| Device Type: |
CRAC |
| Family: |
Liebert iCOM v4 Controller |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Liebert(R) IntelliSlot(TM) Modbus and BACnet Protocols, Reference Guide |
| Version: |
Not Available
|
| Sections: |
Tables 3.1-3.2 (pgs.19-71) |
| URL: |
Not Available
|
Vertiv / Liebert CRAC CRV
| Manufacturer: |
Vertiv / Liebert |
| Device Type: |
CRAC |
| Family: |
CRV |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Vertiv CRV 030 inrow cooler (rdu sic G2) |
| Version: |
Not Available
|
| Sections: |
rows 6-79,96-203, function 3 registers 1-74, function 1 registers 1-108 |
| URL: |
Not Available
|
Vertiv / Liebert Corporation Chiller iCOM SC, type HPC
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
Chiller |
| Family: |
iCOM SC, type HPC |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Web Card |
| Firmware Versions: |
| 5.280.3 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation Chiller iCOM SC, type XDC
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
Chiller |
| Family: |
iCOM SC, type XDC |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Web Card |
| Firmware Versions: |
| 5.280.3 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation CRAC Advanced Microprocessor Cooling
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
CRAC |
| Family: |
Advanced Microprocessor Cooling |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Web/485 Card |
| Firmware Versions: |
| 5.2A0.2 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation CRAC CEMS100/LECS15
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
CRAC |
| Family: |
CEMS100/LECS15 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Web/485 Card |
| Firmware Versions: |
| 5.2A0.7 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation CRAC CRV Row-based Environmental Control System
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
CRAC |
| Family: |
CRV Row-based Environmental Control System |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Web/485 Card |
| Firmware Versions: |
| 5.280.2 |
| OpenComms Web Card |
| Firmware Versions: |
| 5.010.10 |
Additional Information:
Reference Documents:
| Document: |
LIEBERT-GP-ENVIRONMENTAL-MIB |
| Version: |
v.18, Tue Jul 28 21:49:40 EDT 2020 |
| Sections: |
1.3.6.1.4.1.476.1.42.3.4.* |
| URL: |
Not Available
|
Vertiv / Liebert Corporation CRAC iCOM PA, type Challenger
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
CRAC |
| Family: |
iCOM PA, type Challenger |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 7.3.0.0 |
Additional Information:
Reference Documents:
| Document: |
LIEBERT-GP-ENVIRONMENTAL-MIB |
| Version: |
v.18, Tue Jul 28 21:49:40 EDT 2020 |
| Sections: |
1.3.6.1.4.1.476.1.42.3.4.* |
| URL: |
Not Available
|
Vertiv / Liebert Corporation CRAC iCOM PA, type DS
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
CRAC |
| Family: |
iCOM PA, type DS |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Web Card |
| Firmware Versions: |
| 5.280.2 |
Additional Information:
Reference Documents:
| Document: |
LIEBERT-GP-ENVIRONMENTAL-MIB |
| Version: |
v.18, Tue Jul 28 21:49:40 EDT 2020 |
| Sections: |
1.3.6.1.4.1.476.1.42.3.4.* |
| URL: |
Not Available
|
Vertiv / Liebert Corporation CRAC iCOM PA, type DSE
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
CRAC |
| Family: |
iCOM PA, type DSE |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 3.0.0.0 |
| 4.2.0.0 |
Additional Information:
Reference Documents:
| Document: |
LIEBERT-GP-ENVIRONMENTAL-MIB |
| Version: |
v.18, Tue Jul 28 21:49:40 EDT 2020 |
| Sections: |
1.3.6.1.4.1.476.1.42.3.4.* |
| URL: |
Not Available
|
Vertiv / Liebert Corporation CRAC Deluxe System 3
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
CRAC |
| Family: |
Deluxe System 3 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 4.3.0.0 |
Additional Information:
Reference Documents:
| Document: |
LIEBERT-GP-ENVIRONMENTAL-MIB |
| Version: |
v.18, Tue Jul 28 21:49:40 EDT 2020 |
| Sections: |
1.3.6.1.4.1.476.1.42.3.4.* |
| URL: |
Not Available
|
Vertiv / Liebert Corporation CRAC iCOM PA, type HPM
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
CRAC |
| Family: |
iCOM PA, type HPM |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 5.0.0.0 |
Additional Information:
Reference Documents:
| Document: |
LIEBERT-GP-ENVIRONMENTAL-MIB |
| Version: |
v.18, Tue Jul 28 21:49:40 EDT 2020 |
| Sections: |
1.3.6.1.4.1.476.1.42.3.4.* |
| URL: |
Not Available
|
Vertiv / Liebert Corporation CRAC iCOM
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
CRAC |
| Family: |
iCOM |
| Protocol: |
SNMP |
Models Tested:
| Liebert DELUXE |
| Liebert HIMOD |
| Liebert PEX |
| ICOM Environmental Control |
| Liebert DS |
Network Cards:
| IntelliSlot Web Card |
| Firmware Versions: |
| 3.210.0 |
| 5.050.0 |
| OpenComms Web Card |
| Firmware Versions: |
| 3.010.0 |
Additional Information:
Reference Documents:
| Document: |
LIEBERT-GP-ENVIRONMENTAL-MIB |
| Version: |
v.18, Tue Jul 28 21:49:40 EDT 2020 |
| Sections: |
1.3.6.1.4.1.476.1.42.3.4.* |
| URL: |
Not Available
|
Vertiv / Liebert Corporation CRAC MiniMate 2
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
CRAC |
| Family: |
MiniMate 2 |
| Protocol: |
SNMP |
Models Tested:
| Mini-Mate2 Control |
| Mini-Mate2 8-Ton Control |
Network Cards:
| IntelliSlot Web/485 Card |
| Firmware Versions: |
| 3.120.5 |
| 3.120.7 |
| 5.2A0.1 |
| 5.2A0.2 |
| IntelliSlot Unity Card |
| Firmware Versions: |
| 8.0.0.0 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation CRAC MiniMate 3
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
CRAC |
| Family: |
MiniMate 3 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 7.8.0.0-4.2.2 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation CRAC iCOM PA, type PDX
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
CRAC |
| Family: |
iCOM PA, type PDX |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 4.2.0.0 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation CRAC iCOM PA, type PEX
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
CRAC |
| Family: |
iCOM PA, type PEX |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 6.0.0.0 |
Additional Information:
Reference Documents:
| Document: |
LIEBERT-GP-ENVIRONMENTAL-MIB |
| Version: |
v.18, Tue Jul 28 21:49:40 EDT 2020 |
| Sections: |
1.3.6.1.4.1.476.1.42.3.4.* |
| URL: |
Not Available
|
Vertiv / Liebert Corporation CRAC iCOM PA, type PEXS
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
CRAC |
| Family: |
iCOM PA, type PEXS |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 6.6.0.0 |
| 7.8.0.0-4.2.1 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation Power Meter Extended Power Monitoring Panel (EPMP)
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
Power Meter |
| Family: |
Extended Power Monitoring Panel (EPMP) |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Web/485 Card |
| Firmware Versions: |
| 3.120.6 |
| 3.120.7 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation Power Meter Power Monitoring Panel, FDC
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
Power Meter |
| Family: |
Power Monitoring Panel, FDC |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 7.5.0.0 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation Power Meter Power Monitoring Panel, Generic
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
Power Meter |
| Family: |
Power Monitoring Panel, Generic |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 7.5.0.0 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation Power Meter Power Monitoring Panel, PPC
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
Power Meter |
| Family: |
Power Monitoring Panel, PPC |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 8.0.0.2 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation Power Meter Power Monitoring Panel, RDC
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
Power Meter |
| Family: |
Power Monitoring Panel, RDC |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 7.8.0.0 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation Rack PDU MPH
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
Rack PDU |
| Family: |
MPH |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Rack PDU Card |
| Firmware Versions: |
| 4.840.0 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation Rack PDU MPH/MPX (RPC2)
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
Rack PDU |
| Family: |
MPH/MPX (RPC2) |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| RPC2 |
| Firmware Versions: |
| 12.0.0.5 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation Rack PDU MPX
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
Rack PDU |
| Family: |
MPX |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Rack PDU Card |
| Firmware Versions: |
| 4.940.0 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation Rack PDU PMP v4 for STS2/PDU
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
Rack PDU |
| Family: |
PMP v4 for STS2/PDU |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 6.6.0.0 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation Transfer Switch Static Transfer Switch 2
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
Transfer Switch |
| Family: |
Static Transfer Switch 2 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Web/485 Card |
| Firmware Versions: |
| 3.120.7 |
Additional Information:
Reference Documents:
Vertiv Tech Co., Ltd. UPS Liebert ITA2
| Manufacturer: |
Vertiv Tech Co., Ltd. |
| Device Type: |
UPS |
| Family: |
Liebert ITA2 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
ENP_UPS_ITA2[COM]-MIB.mib |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
Wagner Group GmbH EMS OxyReduct M-Line
| Manufacturer: |
Wagner Group GmbH |
| Device Type: |
EMS |
| Family: |
OxyReduct M-Line |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Standarddatenpunktliste_Rev2c.pdf |
| Version: |
Rev. 2c |
| Sections: |
Not Available
|
| URL: |
Not Available
|
| Document: |
Standarddatenpunktliste_Rev2c_translated.pdf |
| Version: |
Rev. 2c (Translated from German to English using Google Translate) |
| Sections: |
Not Available
|
| URL: |
Not Available
|
Woodward ATS DTSC-200
| Manufacturer: |
Woodward |
| Device Type: |
ATS |
| Family: |
DTSC-200 |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
WOODWARD-DTSC200_INTERFACE-MANUAL |
| Version: |
B |
| Sections: |
Appendix A. (Data Protocol 4701) |
| URL: |
Not Available
|
| Document: |
WOODWARD-DTSC200_CONFIGURATION-MANUAL |
| Version: |
D |
| Sections: |
Logical Command Variables |
| URL: |
Not Available
|
Woodward Inc. Generator easYgen 3000XT Series
| Manufacturer: |
Woodward Inc. |
| Device Type: |
Generator |
| Family: |
easYgen 3000XT Series |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
| Modbus RTU over RS485 |
| Modbus TCP over Ethernet |
Additional Information:
Reference Documents:
| Document: |
Woodward easyGen-3000XT Series Manual |
| Version: |
Software Version 2.10-2, Document ID B37574, Revision L - Build 50616 |
| Sections: |
Section 9.2.7, "Protocol 5016 (Basic Visualization)" (pgs.977-997,1007-1016) |
| URL: |
Not Available
|
ukSoftDev RPDU PseudoRPDU
| Manufacturer: |
ukSoftDev |
| Device Type: |
RPDU |
| Family: |
PseudoRPDU |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
PseudoRDPU modbus map.xlsx |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|