This document describes the types of third-party devices that EcoStruxure IT Expert can monitor. Inclusion in this report does not guarantee a specific device can be monitored. For information about new releases, see the
EcoStruxure IT Gateway device library release notes in the EcoStruxure IT Help Center.
Supported Third-Party Devices
Device library v1.11.0.3
August 2021
Airedale CRAC EasiCool EZRE Precision Air Conditioning
| Manufacturer: |
Airedale |
| Device Type: |
CRAC |
| Family: |
EasiCool EZRE Precision Air Conditioning |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
MIB Browser-Export---10.3.16.122---DETAILED.csv |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
Airedale International CRAC SmartCool Precision Air Conditioner
| Manufacturer: |
Airedale International |
| Device Type: |
CRAC |
| Family: |
SmartCool Precision Air Conditioner |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
SmartCool BMS Points |
| Version: |
V6.00 |
| Sections: |
Analogue Variables (pgs.1-2), Integer Variables (pgs.2-4), Digital Variables(pgs.4-7) |
| URL: |
Not Available
|
AKCP EMS Sensor Probe
| Manufacturer: |
AKCP |
| Device Type: |
EMS |
| Family: |
Sensor Probe |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
akcp (07_06_2017).mib |
| Version: |
Not Available
|
| Sections: |
plusSeries (.1.3.6.1.4.1.3854.3)
temperatureTable (.1.3.6.1.4.1.3854.3.5.2)
humidityTable (.1.3.6.1.4.1.3854.3.5.3)
drycontactTable (.1.3.6.1.4.1.3854.3.5.4)
sirenTable (.1.3.6.1.4.1.3854.3.5.11)
relayTable (.1.3.6.1.4.1.3854.3.5.12)
|
| URL: |
Not Available
|
AKCP EMS Sensor Probe
| Manufacturer: |
AKCP |
| Device Type: |
EMS |
| Family: |
Sensor Probe |
| Protocol: |
SNMP |
Models Tested:
| Sensor Probe 2 |
| Sensor Probe 8 |
Network Cards:
Additional Information:
Reference Documents:
| Document: |
akcp (07_06_2017).mib |
| Version: |
Not Available
|
| Sections: |
sensorProbe (.1.3.6.1.4.1.3854.1)
sensorProbeTempTable (.1.3.6.1.4.1.3854.1.2.2.1.16)
sensorProbeHumidityTable (.1.3.6.1.4.1.3854.1.2.2.1.17)
sensorProbeSwitchTable (.1.3.6.1.4.1.3854.1.2.2.1.18)
sensorProbeDrycontactArraySensor (.1.3.6.1.4.1.3854.1.2.2.1.19.37)
|
| URL: |
Not Available
|
Alcatel Switch
| Manufacturer: |
Alcatel |
| Device Type: |
Switch |
| Family: |
Not Available
|
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Alpha Technologies UPS Alpha FXM
| Manufacturer: |
Alpha Technologies |
| Device Type: |
UPS |
| Family: |
Alpha FXM |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| CXC RMU |
| Firmware Versions: |
| 2.01.00 |
| 2.06.00 |
Additional Information:
Reference Documents:
| Document: |
Argus-Power-System-MIB.mib |
| Version: |
201612090000Z - December 9, 2016 |
| Sections: |
1.3.6.1.4.1.7309.6.1.* |
| URL: |
Not Available
|
Arctic Chiller Group Pump Manhattan Modular
| Manufacturer: |
Arctic Chiller Group |
| Device Type: |
Pump |
| Family: |
Manhattan Modular |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
20100507091536 |
| Version: |
Not Available
|
| Sections: |
Pump Module Parameters Table(pg.6) |
| URL: |
Not Available
|
Arctic Chiller Group Chiller Manhattan Modular
| Manufacturer: |
Arctic Chiller Group |
| Device Type: |
Chiller |
| Family: |
Manhattan Modular |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Manhattan Points List |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
ASCO ATS 72EE
| Manufacturer: |
ASCO |
| Device Type: |
ATS |
| Family: |
72EE |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| 72EE |
| Firmware Versions: |
| 607540-056 |
| 894063-014 |
| 894063-015 |
Additional Information:
| A small subset of possible sensors are available at this time. |
Reference Documents:
ASCO Power Technologies (by Schneider Electric) Power Meter G5 Group Controller
| Manufacturer: |
ASCO Power Technologies (by Schneider Electric) |
| Device Type: |
Power Meter |
| Family: |
G5 Group Controller |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Connectivity to the ASCO(R) Power Manager Xp & 7000 Series Group 5 Controller via Modbus(R) |
| Version: |
381339-221I |
| Sections: |
Register Map for Group 5 Controller(pgs.18-19) |
| URL: |
Not Available
|
BachMann RPDU Blue Net
| Manufacturer: |
BachMann |
| Device Type: |
RPDU |
| Family: |
Blue Net |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Basler Electric Generator DGC-2020 Digital Genset Controller
| Manufacturer: |
Basler Electric |
| Device Type: |
Generator |
| Family: |
DGC-2020 Digital Genset Controller |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Instruction Manual For Digital Genset Controller DGC-2020 |
| Version: |
Revision R, October 2011 |
| Sections: |
Legacy Parameter Table(pgs.B72-B85) |
| URL: |
Not Available
|
Baytech RPDU MRP-series
| Manufacturer: |
Baytech |
| Device Type: |
RPDU |
| Family: |
MRP-series |
| Protocol: |
SNMP |
Models Tested:
| R24 MRP-11396A1 |
| R33 MRP-143DB71 |
Network Cards:
| DS72 |
| Firmware Versions: |
| 2.23.09 |
Additional Information:
Reference Documents:
| Document: |
bayuniv-4014.mib |
| Version: |
4.01.4 |
| Sections: |
sBTAModulesRPCTable (.1.3.6.1.4.1.4779.1.3.5.2)
sBTAModulesRPCOutletTable (.1.3.6.1.4.1.4779.1.3.5.3)
sRPCModPortCircuitsTable (.1.3.6.1.4.1.4779.1.3.5.10)
sBTAModulesEnvironmentalObjectsTable (.1.3.6.1.4.1.4779.1.6.1)
|
| URL: |
https://www.baytech.net/docs-and-downloads/
|
Carrier Global Corporation CRAC AquaSnap Chiller
| Manufacturer: |
Carrier Global Corporation |
| Device Type: |
CRAC |
| Family: |
AquaSnap Chiller |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Default JBus Memory Mapping for LEI Gateway |
| Version: |
Rev. C, 08/29/2007 |
| Sections: |
JBus Memory Mapping - 30RB & 30RQ Default Configuration(pgs.10-11) |
| URL: |
Not Available
|
Caterpillar Inc. Generator Electronic Modular Control Panel (EMCP) 3.x
| Manufacturer: |
Caterpillar Inc. |
| Device Type: |
Generator |
| Family: |
Electronic Modular Control Panel (EMCP) 3.x |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
APPLICATION AND INSTALLATION GUIDE, EMCP 3.1, 3.2, 3.3 GENERATOR SET CONTROL (LEBE5255) |
| Version: |
November 2005 |
| Sections: |
Appendix F - Quick Reference Chart of Modbus Registers (pgs.147-161) |
| URL: |
Not Available
|
| Document: |
EMCP3MODBUSext21Prod2007-05-22-v2_Compare_DDF.xls |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
Chatsworth RPDU
| Manufacturer: |
Chatsworth |
| Device Type: |
RPDU |
| Family: |
Not Available
|
| Protocol: |
SNMP |
Models Tested:
| P3-1H0E3-B2A |
| P6-1F0A1-C2A |
| P4-1P0F3-C3E |
| P5-2R0C3-C7H |
Network Cards:
| eConnect |
| Firmware Versions: |
| 1.17.232 |
| 1.23.146 |
| 2.22.216 |
| 2.23.126 |
Additional Information:
Reference Documents:
Cisco Switch Catalyst
| Manufacturer: |
Cisco |
| Device Type: |
Switch |
| Family: |
Catalyst |
| Protocol: |
SNMP |
Models Tested:
| WS-C2960G-24TC-L |
| WS-C3560G-48TS-E |
| WS-C4500X-32 |
Network Cards:
| Network Management Module |
Additional Information:
Reference Documents:
| Document: |
CISCO-ENERGYWISE-MIB_my.txt |
| Version: |
200901080000Z |
| Sections: |
Not Available
|
| URL: |
Not Available
|
| Document: |
CISCO-ENTITY-SENSOR-MIB.mib |
| Version: |
200509080000Z |
| Sections: |
Not Available
|
| URL: |
Not Available
|
| Document: |
CISCO-ENVMON-MIB.mib |
| Version: |
200311250000Z |
| Sections: |
Not Available
|
| URL: |
Not Available
|
Cummins Power Generation Generator PCC 1301/PowerCommand 1.x
| Manufacturer: |
Cummins Power Generation |
| Device Type: |
Generator |
| Family: |
PCC 1301/PowerCommand 1.x |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Cummins Power Generation Generator PowerCommand
| Manufacturer: |
Cummins Power Generation |
| Device Type: |
Generator |
| Family: |
PowerCommand |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Cyberex PDU Series PDM II
| Manufacturer: |
Cyberex |
| Device Type: |
PDU |
| Family: |
Series PDM II |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Cyberex PDM II Series Owner’s/Operator’s Manual |
| Version: |
05/17/10 Rev.G |
| Sections: |
Appendix B: Modbus Register Map (pgs.58-61) |
| URL: |
Not Available
|
DB Power Electronics UPS 120KVA
| Manufacturer: |
DB Power Electronics |
| Device Type: |
UPS |
| Family: |
120KVA |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
Additional Information:
Reference Documents:
| Document: |
Dbpemib.mib |
| Version: |
2.0.0 |
| Sections: |
upsIdent (.1.3.6.1.4.1.5763.1.1)
upsBattery (.1.3.6.1.4.1.5763.1.2)
upsInput (.1.3.6.1.4.1.5763.1.3)
upsOutput (.1.3.6.1.4.1.5763.1.4)
upsBypass (.1.3.6.1.4.1.5763.1.5)
upsWellKnownAlarms (.1.3.6.1.4.1.5763.1.6)
|
| URL: |
Not Available
|
Deep Sea Electronics Genset Control Module 7450 (GenComm)
| Manufacturer: |
Deep Sea Electronics |
| Device Type: |
Genset Control Module |
| Family: |
7450 (GenComm) |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
GenComm standard for use with generating set control equipment |
| Version: |
2.156, 25 May 2017 |
| Sections: |
Not Available
|
| URL: |
Not Available
|
Deep Sea Electronics Genset Control Module 72xx, 73xx, 61xx, 74xx MkII (GenComm)
| Manufacturer: |
Deep Sea Electronics |
| Device Type: |
Genset Control Module |
| Family: |
72xx, 73xx, 61xx, 74xx MkII (GenComm) |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
GenComm standard for use with generating set control equipment |
| Version: |
2.156, 25 May 2017 |
| Sections: |
Not Available
|
| URL: |
Not Available
|
Deif A/S Generator AGC Series
| Manufacturer: |
Deif A/S |
| Device Type: |
Generator |
| Family: |
AGC Series |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Options H2 and H9 Modbus Communication |
| Version: |
4189340442O |
| Sections: |
Measurement Table (read only) (pgs.43-54), Alarm and Status Table (read only) (pgs.62-88) |
| URL: |
Not Available
|
Denco / Fläkt Group CRAC Multi-DENCO, A-Version
| Manufacturer: |
Denco / Fläkt Group |
| Device Type: |
CRAC |
| Family: |
Multi-DENCO, A-Version |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Denco C5-12 Controller (Carel pcoWeb) |
Additional Information:
Reference Documents:
| Document: |
CAREL-dencoccu-MIB |
| Version: |
201308151024Z |
| Sections: |
Not Available
|
| URL: |
Not Available
|
Eaton RPDU EPDU
| Manufacturer: |
Eaton |
| Device Type: |
RPDU |
| Family: |
EPDU |
| Protocol: |
SNMP |
Models Tested:
| eAM002 |
| eMAA13 |
| eSWA04 |
| EMIB08 |
| EMOB20 |
| EMI101-10 |
| EMI102-10 |
| EMI104-10 |
| EMA107-10 |
| EMI310-10 |
| EMAT08-10 |
Network Cards:
| Network Management Module |
| Firmware Versions: |
| 00.00.0024 |
| 00.10.0001 |
| 00.12.0001 |
| 01.00.0026 |
| 01.00.0031 |
| 01.00.0034 |
| 02.00.0036 |
| 02.00.0038 |
| 02.00.0041 |
| 02.00.0053 |
Additional Information:
Reference Documents:
| Document: |
EATON-EPDU-MIB.mib |
| Version: |
201409291200Z |
| Sections: |
eatonEpdu (.1.3.6.1.4.1.534.6.6.7)
units (.1.3.6.1.4.1.534.6.6.7.1)
inputs (.1.3.6.1.4.1.534.6.6.7.3)
groups (.1.3.6.1.4.1.534.6.6.7.5)
outlets (.1.3.6.1.4.1.534.6.6.7.6)
environmental (.1.3.6.1.4.1.534.6.6.7.7)
|
| URL: |
Not Available
|
Eaton Inverter Eaton System Controllers
| Manufacturer: |
Eaton |
| Device Type: |
Inverter |
| Family: |
Eaton System Controllers |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
RPS-SC200-MIB.txt |
| Version: |
Not Available
|
| Sections: |
1.3.6.1.4.1.1918.2.13.* |
| URL: |
Not Available
|
Eaton EMS-PDU
| Manufacturer: |
Eaton |
| Device Type: |
Not Available
|
| Family: |
EMS-PDU |
| Protocol: |
SNMP |
Models Tested:
| EMS-PDU |
| EMS-PDU with Breaker |
Network Cards:
| Power Xpert Gateway Series 1000 Card |
Additional Information:
Reference Documents:
Eaton Corporation Power Meter DigiTrip 1150 PXG
| Manufacturer: |
Eaton Corporation |
| Device Type: |
Power Meter |
| Family: |
DigiTrip 1150 PXG |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
MNA03669- Register number details per specifications |
| Version: |
Not Available
|
| Sections: |
Breakers-Digitrip 1150 (cells E9:J33) |
| URL: |
Not Available
|
Eaton Corporation UPS Powerware
| Manufacturer: |
Eaton Corporation |
| Device Type: |
UPS |
| Family: |
Powerware |
| Protocol: |
SNMP |
Models Tested:
| 5PX 1500 |
| 5P 1500 R Li-ion |
| PXGX 2000 Eaton 9315 |
| PXGX 2000 Powerware Plus |
| PXGX 2000 Eaton UPS |
| PXGX 2000 Eaton 9390 |
| 9SX 3000iR |
Network Cards:
| Eaton Power Xpert Gateway UPS X-Slot Card |
| Firmware Versions: |
| INV: 07 |
| 1.06.0018 |
| INV: 1.10 NET: 1.4.2.1-ups |
| INV: 1.14 NET: 1.2.0-ups |
| INV: 1.28 NET: 1.4.2.1-ups |
| INV: 2.12 NET: 2.4.0.1-ups |
Additional Information:
Reference Documents:
Eaton Corporation Protective Relay FP 5000-series
| Manufacturer: |
Eaton Corporation |
| Device Type: |
Protective Relay |
| Family: |
FP 5000-series |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Power Xpert Gateway 400/600 |
| Version: |
Not Available
|
| Sections: |
FP5000(pgs.1,5) |
| URL: |
Not Available
|
Eaton Corporation Power Meter Power Xpert 4000/6000/8000
| Manufacturer: |
Eaton Corporation |
| Device Type: |
Power Meter |
| Family: |
Power Xpert 4000/6000/8000 |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Power Xpert Registers |
| Version: |
IB02601003E |
| Sections: |
B.1. Standard Modbus Register Map (pgs.185-190) |
| URL: |
Not Available
|
Eaton Corporation / Pulizzi Engineering Rack PDU Switched ePDU
| Manufacturer: |
Eaton Corporation / Pulizzi Engineering |
| Device Type: |
Rack PDU |
| Family: |
Switched ePDU |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Electro Industries/GaugeTech Inc. Power Meter Shark 200 Switchboard Power Meter
| Manufacturer: |
Electro Industries/GaugeTech Inc. |
| Device Type: |
Power Meter |
| Family: |
Shark 200 Switchboard Power Meter |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
| Modbus RTU over RS485 |
| Modbus TCP over Ethernet |
Additional Information:
Reference Documents:
| Document: |
Shark 200/200T |
| Version: |
V.1.30, July 3, 2020 |
| Sections: |
Shark(R) 200 Meter Modbus Register Map (pgs. 252-294) |
| URL: |
Not Available
|
Electro Industries/GaugeTech Inc. Power Meter Shark 100 Switchboard Power Meter
| Manufacturer: |
Electro Industries/GaugeTech Inc. |
| Device Type: |
Power Meter |
| Family: |
Shark 100 Switchboard Power Meter |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
| Modbus RTU over RS485 |
| Modbus TCP over Ethernet |
Additional Information:
Reference Documents:
| Document: |
Shark 100/100T/100B/100BT/50/50B |
| Version: |
V.1.34, February 4, 2021 |
| Sections: |
Shark(R) 100 Meter Modbus Map (pgs. 175-181) |
| URL: |
Not Available
|
ELNet / FENIKS PRO Ltd. Power Meter LTE Power Meter
| Manufacturer: |
ELNet / FENIKS PRO Ltd. |
| Device Type: |
Power Meter |
| Family: |
LTE Power Meter |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Emerson / Liebert / Vertiv UPS Series 600 / Series 610
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
UPS |
| Family: |
Series 600 / Series 610 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Web Card |
| Firmware Versions: |
| 3.120.6 |
| OpenComms Web Card |
| Firmware Versions: |
| 3.020.0 |
Additional Information:
Reference Documents:
Emerson / Liebert / Vertiv UPS Series 7200
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
UPS |
| Family: |
Series 7200 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Web/485 Card |
| Firmware Versions: |
| 3.120.7 |
| 5.2A0.2 |
Additional Information:
Reference Documents:
Emerson / Liebert / Vertiv UPS Series 610 SMS
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
UPS |
| Family: |
Series 610 SMS |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Web/485 Card |
| Firmware Versions: |
| 3.120.7 |
Additional Information:
Reference Documents:
Emerson / Liebert / Vertiv UPS UPStation GXT
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
UPS |
| Family: |
UPStation GXT |
| Protocol: |
SNMP |
Models Tested:
| GXT2-1000RT120 |
| GXT3-3000RT120 |
| GXT3-3000RT230 |
Network Cards:
| IntelliSlot Web Card |
| Firmware Versions: |
| 3.100.2 |
| 5.200.0 |
| 5.300.0 |
Additional Information:
Reference Documents:
Emerson / Liebert / Vertiv UPS NXR
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
UPS |
| Family: |
NXR |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Web Card |
| Firmware Versions: |
| 5.180.1 |
| 5.280.2 |
Additional Information:
Reference Documents:
Emerson / Liebert / Vertiv UPS NXL
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
UPS |
| Family: |
NXL |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IS-UNITY-DP |
| Firmware Versions: |
| 6.1.0.0 |
Additional Information:
Reference Documents:
Emerson / Liebert / Vertiv UPS eXM M/S/R
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
UPS |
| Family: |
eXM M/S/R |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 7.7.0.0 |
Additional Information:
Reference Documents:
Emerson / Liebert / Vertiv UPS Npower
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
UPS |
| Family: |
Npower |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| OpenComms Web Card |
| Firmware Versions: |
| 2.200.0 |
Additional Information:
Reference Documents:
Emerson / Liebert / Vertiv UPS NX
| Manufacturer: |
Emerson / Liebert / Vertiv |
| Device Type: |
UPS |
| Family: |
NX |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Web Card |
| Firmware Versions: |
| 5.010.1 |
Additional Information:
Reference Documents:
Enlogic PDU Advantage Series
| Manufacturer: |
Enlogic |
| Device Type: |
PDU |
| Family: |
Advantage Series |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
| Firmware Versions: |
| 1.0.6.1 |
Additional Information:
Reference Documents:
| Document: |
1606761202-Enlogic_2.0_v1_0.mib |
| Version: |
202010300000Z |
| Sections: |
pduNamePlate (.1.3.6.1.4.1.38446.1.1)
pduUnit (.1.3.6.1.4.1.38446.1.2)
pduInputPhase (.1.3.6.1.4.1.38446.1.3)
pduCircuitBreaker (.1.3.6.1.4.1.38446.1.4)
pduOutlet (.1.3.6.1.4.1.38446.1.5)
pduExternalSensor (.1.3.6.1.4.1.38446.1.6)
|
| URL: |
https://www.enlogic.com/public/assets/images/1606761202-Enlogic_2.0_v1_0.mib
|
Enlogic PDU Legacy
| Manufacturer: |
Enlogic |
| Device Type: |
PDU |
| Family: |
Legacy |
| Protocol: |
SNMP |
Models Tested:
| EN1111 |
| EN1183 |
| EN4001 |
| EN6109 |
| EN6113 |
| EZ1157 |
Network Cards:
| Network Management Module |
| Firmware Versions: |
| 6.ca |
| 6.d0 |
| 7.08 |
| 7.11T26 |
| 7.12R31 |
| 7.12R3F |
| 7.12T39 |
| 7.80T15 |
Additional Information:
Reference Documents:
| Document: |
1590139060-Enlogic_legacy_mib.mib |
| Version: |
201506180000Z |
| Sections: |
pduNamePlate (.1.3.6.1.4.1.38446.1.1)
pduUnit (.1.3.6.1.4.1.38446.1.2)
pduInputPhase (.1.3.6.1.4.1.38446.1.3)
pduCircuitBreaker (.1.3.6.1.4.1.38446.1.4)
pduOutlet (.1.3.6.1.4.1.38446.1.5)
pduExternalSensor (.1.3.6.1.4.1.38446.1.6)
|
| URL: |
https://www.enlogic.com/public/assets/images/1590139060-Enlogic_legacy_mib.mib
|
Enlogic PDU Edge Series
| Manufacturer: |
Enlogic |
| Device Type: |
PDU |
| Family: |
Edge Series |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
Additional Information:
Reference Documents:
Enlogic Power Meter Inline
| Manufacturer: |
Enlogic |
| Device Type: |
Power Meter |
| Family: |
Inline |
| Protocol: |
SNMP |
Models Tested:
| EZ1152 |
| EZ1154 |
| EZ1254 |
| EZ1255 |
Network Cards:
| Network Management Module |
| Firmware Versions: |
| 9.10 |
| 9.10R02 |
| 7.12R31 |
Additional Information:
Reference Documents:
| Document: |
1590139060-Enlogic_legacy_mib.mib |
| Version: |
201506180000Z |
| Sections: |
pduNamePlate (.1.3.6.1.4.1.38446.1.1)
pduUnit (.1.3.6.1.4.1.38446.1.2)
pduInputPhase (.1.3.6.1.4.1.38446.1.3)
pduCircuitBreaker (.1.3.6.1.4.1.38446.1.4)
pduOutlet (.1.3.6.1.4.1.38446.1.5)
pduExternalSensor (.1.3.6.1.4.1.38446.1.6)
|
| URL: |
https://www.enlogic.com/public/assets/images/1590139060-Enlogic_legacy_mib.mib
|
Geist RPDU IMD PDU
| Manufacturer: |
Geist |
| Device Type: |
RPDU |
| Family: |
IMD PDU |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
geist_imd_mib.mib |
| Version: |
201209110000Z |
| Sections: |
dewPointSensorTable (.1.3.6.1.4.1.21239.5.2.6)
ccatSensorTable (.1.3.6.1.4.1.21239.5.2.7)
rpmSensorTable (.1.3.6.1.4.1.21239.5.2.10)
|
| URL: |
Not Available
|
| Document: |
geist_v5.mib |
| Version: |
201906060000Z |
| Sections: |
pduMainTable (.1.3.6.1.4.1.21239.5.2.3.1)
pduPhaseTable (.1.3.6.1.4.1.21239.5.2.3.2)
pduBreakerTable (.1.3.6.1.4.1.21239.5.2.3.3)
tempSensorTable (.1.3.6.1.4.1.21239.5.2.4)
airFlowSensorTable (.1.3.6.1.4.1.21239.5.2.5)
t3hdSensorTable (.1.3.6.1.4.1.21239.5.2.8)
thdSensorTable (.1.3.6.1.4.1.21239.5.2.9)
|
| URL: |
Not Available
|
Geist RPDU Upgradeable / R-Series v5.0
| Manufacturer: |
Geist |
| Device Type: |
RPDU |
| Family: |
Upgradeable / R-Series v5.0 |
| Protocol: |
SNMP |
Models Tested:
| EG2RCUC206-103P8BPS6-OD-IF-02-IP44 |
| MGU3EHW1-48MI13-3PS56B2A10-S-A |
| EGRCMBN243-102PH6PS56-OD-IP44 |
Network Cards:
Additional Information:
Reference Documents:
| Document: |
geist_v5.mib |
| Version: |
201906060000Z |
| Sections: |
pduMainTable (.1.3.6.1.4.1.21239.5.2.3.1)
pduPhaseTable (.1.3.6.1.4.1.21239.5.2.3.2)
pduBreakerTable (.1.3.6.1.4.1.21239.5.2.3.3)
tempSensorTable (.1.3.6.1.4.1.21239.5.2.4)
airFlowSensorTable (.1.3.6.1.4.1.21239.5.2.5)
t3hdSensorTable (.1.3.6.1.4.1.21239.5.2.8)
thdSensorTable (.1.3.6.1.4.1.21239.5.2.9)
|
| URL: |
Not Available
|
Green Revolution Cooling CRAC ICEraQ Micro 24U
| Manufacturer: |
Green Revolution Cooling |
| Device Type: |
CRAC |
| Family: |
ICEraQ Micro 24U |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
GRC.xlsx |
| Version: |
Not Available
|
| Sections: |
Not Available
|
| URL: |
Not Available
|
Grundfos Pump CIM-500
| Manufacturer: |
Grundfos |
| Device Type: |
Pump |
| Family: |
CIM-500 |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Modbus for Grundfos pumps_IO_GB_Internet.pdf |
| Version: |
Not Available
|
| Sections: |
Section 9, "Modbus register addresses" and Section 16, "Grundfos alarm and warning codes" |
| URL: |
Not Available
|
Hewlett-Packard Enterprise Rack PDU v1
| Manufacturer: |
Hewlett-Packard Enterprise |
| Device Type: |
Rack PDU |
| Family: |
v1 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
CPQPOWER_MIB |
| Version: |
1.76 |
| Sections: |
1.3.6.1.4.1.232.165.2.* |
| URL: |
Not Available
|
Hewlett-Packard Enterprise PDU Modular
| Manufacturer: |
Hewlett-Packard Enterprise |
| Device Type: |
PDU |
| Family: |
Modular |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
CPQPOWER_MIB |
| Version: |
1.76 |
| Sections: |
1.3.6.1.4.1.232.165.5.* |
| URL: |
Not Available
|
Hewlett-Packard Enterprise Rack PDU v2
| Manufacturer: |
Hewlett-Packard Enterprise |
| Device Type: |
Rack PDU |
| Family: |
v2 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
CPQPOWER_MIB |
| Version: |
1.76 |
| Sections: |
1.3.6.1.4.1.232.165.7.* |
| URL: |
Not Available
|
Himoinsa Generator CEM/CEC/CEA Genset Control Unit
| Manufacturer: |
Himoinsa |
| Device Type: |
Generator |
| Family: |
CEM/CEC/CEA Genset Control Unit |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
| CCLan Modbus Option Module |
Additional Information:
Reference Documents:
| Document: |
CAN/LAN MODBUS: CCLAN: Opción de comunicaciones por protocolo MODBus IP |
| Version: |
1.4_es |
| Sections: |
section 2.2, "Mapa de registros" (pgs.8-16) |
| URL: |
Not Available
|
Hiref SpA CRAC NADR
| Manufacturer: |
Hiref SpA |
| Device Type: |
CRAC |
| Family: |
NADR |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Hiref HiNode (Carel pcoWeb) |
Additional Information:
Reference Documents:
| Document: |
CAREL-std-air-cond-MIB |
| Version: |
201005190920Z |
| Sections: |
Not Available
|
| URL: |
Not Available
|
HW group s.r.o. SNMP Thermometer HWg-STE
| Manufacturer: |
HW group s.r.o. |
| Device Type: |
SNMP Thermometer |
| Family: |
HWg-STE |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
STE-MIB |
| Version: |
v.1.03, 17 Jul 2013 |
| Sections: |
.1.3.6.1.4.1.21796.4.1.* |
| URL: |
Not Available
|
ITWatchDogs (Vertiv Geist) EMS SuperGoose II
| Manufacturer: |
ITWatchDogs (Vertiv Geist) |
| Device Type: |
EMS |
| Family: |
SuperGoose II |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
Additional Information:
Reference Documents:
| Document: |
itw_mibv3.mib |
| Version: |
200801100000Z |
| Sections: |
.1.3.6.1.4.1.17373.3.* |
| URL: |
Not Available
|
ITWatchDogs (Vertiv Geist) EMS WxGoos
| Manufacturer: |
ITWatchDogs (Vertiv Geist) |
| Device Type: |
EMS |
| Family: |
WxGoos |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
Additional Information:
Reference Documents:
| Document: |
itw_mib.mib |
| Version: |
200709040000Z |
| Sections: |
.1.3.6.1.4.1.17373.2.* |
| URL: |
Not Available
|
Janitza Power Meter UMG96
| Manufacturer: |
Janitza |
| Device Type: |
Power Meter |
| Family: |
UMG96 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
Additional Information:
| Like pCOWeb devices, OIDs are shared across different models but measure different parameters |
Reference Documents:
| Document: |
UMG96RM_09092013.mib |
| Version: |
09092013 |
| Sections: |
rmsPhase (.1.3.6.1.4.1.34278.1.*)
rmsSum (.1.3.6.1.4.1.34278.2.*)
energyPhase (.1.3.6.1.4.1.34278.3.*)
energySum (.1.3.6.1.4.1.34278.4.*)
thd (.1.3.6.1.4.1.34278.5.*)
misc (.1.3.6.1.4.1.34278.6.*)
|
| URL: |
https://www.janitza.com/snmpmib-download.html
|
Janitza Electronics GmbH Power Meter UMG 507
| Manufacturer: |
Janitza Electronics GmbH |
| Device Type: |
Power Meter |
| Family: |
UMG 507 |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
| discontinued by manufacturer |
Reference Documents:
| Document: |
UMG507 Register map |
| Version: |
Software Release 0.934, November 18 2004 |
| Sections: |
Modbus Address List (pgs.1,4,) |
| URL: |
Not Available
|
Janitza Electronics GmbH Power Meter UMG 604
| Manufacturer: |
Janitza Electronics GmbH |
| Device Type: |
Power Meter |
| Family: |
UMG 604 |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Janitza Electronics GmbH Power Meter UMG 96RM
| Manufacturer: |
Janitza Electronics GmbH |
| Device Type: |
Power Meter |
| Family: |
UMG 96RM |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Kamstrup Heat Meter MULTICAL
| Manufacturer: |
Kamstrup |
| Device Type: |
Heat Meter |
| Family: |
MULTICAL |
| Protocol: |
MODBUS |
Models Tested:
| MULTICAL 62 |
| MULTICAL 601 |
| MULTICAL 602 |
| MULTICAL 801 |
Network Cards:
Additional Information:
Reference Documents:
Kidde-Fenwal Inc. Generic ARIES
| Manufacturer: |
Kidde-Fenwal Inc. |
| Device Type: |
Generic |
| Family: |
ARIES |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
kidde-fenwal_ARIES.pdf |
| Version: |
Not Available
|
| Sections: |
Pages 14-19 |
| URL: |
Not Available
|
Kohler Power Systems Generator Decision Maker
| Manufacturer: |
Kohler Power Systems |
| Device Type: |
Generator |
| Family: |
Decision Maker |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
| Modbus RTU over RS485 |
| Modbus TCP over Ethernet |
Additional Information:
Reference Documents:
| Document: |
tp6113.pdf |
| Version: |
Not Available
|
| Sections: |
Modbus Registers (pgs. 47-60) |
| URL: |
Not Available
|
Lenovo RPDU Lenovo RPDU
| Manufacturer: |
Lenovo |
| Device Type: |
RPDU |
| Family: |
Lenovo RPDU |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
| Firmware Versions: |
| 02.00.0038 |
Additional Information:
Reference Documents:
| Document: |
EATON-EPDU-MIB.mib |
| Version: |
201409291200Z |
| Sections: |
eatonEpdu (.1.3.6.1.4.1.534.6.6.7)
units (.1.3.6.1.4.1.534.6.6.7.1)
inputs (.1.3.6.1.4.1.534.6.6.7.3)
groups (.1.3.6.1.4.1.534.6.6.7.5)
outlets (.1.3.6.1.4.1.534.6.6.7.6)
environmental (.1.3.6.1.4.1.534.6.6.7.7)
|
| URL: |
Not Available
|
Luminous UPS
| Manufacturer: |
Luminous |
| Device Type: |
UPS |
| Family: |
Not Available
|
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
| Firmware Versions: |
| 00862.04 |
Additional Information:
Reference Documents:
| Document: |
UPSmib.MIB |
| Version: |
20100560000Z |
| Sections: |
ups (.1.3.6.1.4.1.43943.1.1.*) |
| URL: |
Not Available
|
Mitsubishi UPS
| Manufacturer: |
Mitsubishi |
| Device Type: |
UPS |
| Family: |
Not Available
|
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
| In netcom-manual-rev-51.pdf, MIB is located in Appendix D, "MIBS"; pg.53 |
Reference Documents:
Mitsubishi Electric UPS 9900-series
| Manufacturer: |
Mitsubishi Electric |
| Device Type: |
UPS |
| Family: |
9900-series |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
| Niobrara MUCM (Modbus RTU over RS485) |
Additional Information:
Reference Documents:
Mitsubishi Electric UPS 9800-series
| Manufacturer: |
Mitsubishi Electric |
| Device Type: |
UPS |
| Family: |
9800-series |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
| Niobrara MUCM (Modbus RTU over RS485) |
Additional Information:
Reference Documents:
Network Technologies Incorporated (NTI) EMS ENVIROMUX-2D
| Manufacturer: |
Network Technologies Incorporated (NTI) |
| Device Type: |
EMS |
| Family: |
ENVIROMUX-2D |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
Additional Information:
Reference Documents:
Network Technologies Incorporated (NTI) EMS ENVIROMUX-5D
| Manufacturer: |
Network Technologies Incorporated (NTI) |
| Device Type: |
EMS |
| Family: |
ENVIROMUX-5D |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
Additional Information:
Reference Documents:
Network Technologies Incorporated (NTI) EMS ENVIROMUX-16D
| Manufacturer: |
Network Technologies Incorporated (NTI) |
| Device Type: |
EMS |
| Family: |
ENVIROMUX-16D |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
Additional Information:
Reference Documents:
Oracle RPDU Enhanced PDU
| Manufacturer: |
Oracle |
| Device Type: |
RPDU |
| Family: |
Enhanced PDU |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
snmp_oracle_rmii.mib |
| Version: |
Not Available
|
| Sections: |
pduSystem (.1.3.6.1.4.1.2769.1.4.1)
pduTotalPower (.1.3.6.1.4.1.2769.1.4.5.1)
pduPowerInputs (.1.3.6.1.4.1.2769.1.4.5.2)
pduLines (.1.3.6.1.4.1.2769.1.4.5.3)
|
| URL: |
Not Available
|
PacketPower LLC Power Meter Modbus Ethernet Gateway, v.4
| Manufacturer: |
PacketPower LLC |
| Device Type: |
Power Meter |
| Family: |
Modbus Ethernet Gateway, v.4 |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
| Modbus Ethernet Gateway, v.4 |
Additional Information:
Reference Documents:
PDI BCM Branch Circuit Monitor System II Plus (BCMSII Plus)
| Manufacturer: |
PDI |
| Device Type: |
BCM |
| Family: |
Branch Circuit Monitor System II Plus (BCMSII Plus) |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
PDI STS WaveStar
| Manufacturer: |
PDI |
| Device Type: |
STS |
| Family: |
WaveStar |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Wavestar_Rev4.mib |
| Version: |
February 26, 2013 |
| Sections: |
analog-values (.1.3.6.1.4.1.11273.1.2.1.1)
analog-alarms (.1.3.6.1.4.1.11273.1.2.1.2)
digital-values (.1.3.6.1.4.1.11273.1.2.1.3)
digital-alarms (.1.3.6.1.4.1.11273.1.2.1.4)
|
| URL: |
https://www.pdicorp.com/services/service-software-downloads/
|
PDI Display WaveStar Color Monitor
| Manufacturer: |
PDI |
| Device Type: |
Display |
| Family: |
WaveStar Color Monitor |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
PDI-FDI-DISPLAY-14-a.mib |
| Version: |
Revision B 27/10/2014 |
| Sections: |
pdu1 (.1.3.6.1.4.1.24436.1.5.3.2.11)
bcmskwh1 (.1.3.6.1.4.1.24436.1.5.3.2.8)
bcmskwh2 (.1.3.6.1.4.1.24436.1.5.3.3.8)
bcmskwh3 (.1.3.6.1.4.1.24436.1.5.3.4.8)
bcmskwh4 (.1.3.6.1.4.1.24436.1.5.3.5.8)
|
| URL: |
Not Available
|
PDI Corp. / Eaton Branch Circuit Monitor Branch Circuit Monitor System II (BCMSII)
| Manufacturer: |
PDI Corp. / Eaton |
| Device Type: |
Branch Circuit Monitor |
| Family: |
Branch Circuit Monitor System II (BCMSII) |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
| Data Acquisition Module (Modbus RTU over RS485) |
Additional Information:
Reference Documents:
PDI Corp. / Eaton Branch Circuit Monitor Branch Circuit Monitor System II Plus (BCMSII Plus)
| Manufacturer: |
PDI Corp. / Eaton |
| Device Type: |
Branch Circuit Monitor |
| Family: |
Branch Circuit Monitor System II Plus (BCMSII Plus) |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
| Data Acquisition Module (Modbus RTU over RS485) |
Additional Information:
Reference Documents:
Phoenix Broadband Technologies BMS PowerAgent
| Manufacturer: |
Phoenix Broadband Technologies |
| Device Type: |
BMS |
| Family: |
PowerAgent |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
pbtRootMIB.mib |
| Version: |
Jan. 9 2009 |
| Sections: |
Not Available
|
| URL: |
Not Available
|
| Document: |
pbtBatteryAgentMIB.mib |
| Version: |
Feb. 17 2009 |
| Sections: |
Not Available
|
| URL: |
Not Available
|
PhoenixTec Power Co. UPS UPSMate
| Manufacturer: |
PhoenixTec Power Co. |
| Device Type: |
UPS |
| Family: |
UPSMate |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
XPPC-MIB |
| Version: |
Version 2.00, May 16, 2003 |
| Sections: |
1.3.6.1.4.1.935.* |
| URL: |
Not Available
|
PowerShield Limited Battery String Monitor PowerShield8
| Manufacturer: |
PowerShield Limited |
| Device Type: |
Battery String Monitor |
| Family: |
PowerShield8 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| PowerShield Controller LX |
| PowerShield Controller MX |
Additional Information:
Reference Documents:
| Document: |
PS-B1002-MIB |
| Version: |
201706210000Z |
| Sections: |
1.3.6.1.4.1.35154.1002.* |
| URL: |
Not Available
|
Qualitrol Company LLC Intelligent Transformer Monitor 118 ITM
| Manufacturer: |
Qualitrol Company LLC |
| Device Type: |
Intelligent Transformer Monitor |
| Family: |
118 ITM |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Raritan Inc. Rack PDU PX2/PX3
| Manufacturer: |
Raritan Inc. |
| Device Type: |
Rack PDU |
| Family: |
PX2/PX3 |
| Protocol: |
SNMP |
Models Tested:
| PX2-1486 |
| PX2-1551 |
| PX2-1724 |
| PX2-1971I2U-E2V2A7 |
| PX2-2145R |
| PX2-3123 |
| PX2-4397 |
| PX2-4523T-N3K701 |
| PX2-4551-E2N1V2K9 |
| PX2-4724-E2N1K9 |
| PX2-5493-K1 |
| PX2-5530 |
| PX2-5701 |
| PX2-5732-F5 |
| PX3-5041V-F5M5 |
| PX3-5145R |
| PX3-5730V-K1 |
Network Cards:
| Raritan iX7 Intelligent Field Replaceable Controller |
| Firmware Versions: |
| 2.3.1.5-37516 |
| 2.3.7.5-39116 |
| 2.4.1.5-39763 |
| 2.4.3.5-40298 |
| 3.0.1.5-41478 |
| 3.0.4.5-41800 |
| 3.1.0.5-42165 |
| 3.4.0.5-44367 |
| 3.5.0.5-45371 |
Additional Information:
|
2000-series and 5000-series RPDUs have switchable outlets.
4000-series and 5000-series RPDUs have per-Outlet metering.
1000-series RPDUs have neither of these.
|
Reference Documents:
Redetec Limited Fire Suppression System PN/Red/3.0
| Manufacturer: |
Redetec Limited |
| Device Type: |
Fire Suppression System |
| Family: |
PN/Red/3.0 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
XYTRONIX-MIB |
| Version: |
Not Available
|
| Sections: |
1.3.6.1.4.1.30586.21.* |
| URL: |
Not Available
|
Redetec Limited Fire Suppression System PN/Red/3.0/FAL
| Manufacturer: |
Redetec Limited |
| Device Type: |
Fire Suppression System |
| Family: |
PN/Red/3.0/FAL |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
XYTRONIX-MIB |
| Version: |
Not Available
|
| Sections: |
1.3.6.1.4.1.30586.54.* |
| URL: |
Not Available
|
Rittal PDU Smart PDU
| Manufacturer: |
Rittal |
| Device Type: |
PDU |
| Family: |
Smart PDU |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
Additional Information:
| Created based on list of connected devices via DCE. Cannot find much information on this device. |
Reference Documents:
| Document: |
ED-3S625A-DE32PV.MIB |
| Version: |
Not Available
|
| Sections: |
sPDU (1.3.6.1.4.1.40367.1.1.12.*)
|
| URL: |
Not Available
|
Rittal Chiller Kelvin
| Manufacturer: |
Rittal |
| Device Type: |
Chiller |
| Family: |
Kelvin |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
snmp_mibs_RITTAL-pCOWeb-Chiller-MIB.mib |
| Version: |
201309131602Z |
| Sections: |
digitalObjects (.1.3.6.1.4.1.2606.20.2.1.1)
analogObjects (.1.3.6.1.4.1.2606.20.2.1.2)
integerObjects (.1.3.6.1.4.1.2606.20.2.1.3)
|
| URL: |
Not Available
|
Rittal GmbH & Co. KG Monitoring System Computer Multi-Control III
| Manufacturer: |
Rittal GmbH & Co. KG |
| Device Type: |
Monitoring System |
| Family: |
Computer Multi-Control III |
| Protocol: |
SNMP |
Models Tested:
| 3311.230 - Liquid Cooling Package |
| 3312.230 - Liquid Cooling Package |
| 7030.000 - Processing Unit |
| 7030.040 - I/O Input |
| 7030.110 - Temperature Probe |
| 7030.111 - Temp/Humidity Probe |
| 7030.430/440 - Leak Sensor |
| 7338.121 - DET-AC III Master Fire Alarm/Extinguisher |
| 7998.106 - RiMatrix S S6W |
Network Cards:
| CMC III Processing Unit |
| Firmware Versions: |
| V3.15.70_4 |
| V3.17.10 |
| V5.15.40_2 |
Additional Information:
Reference Documents:
Server Technology Inc. (ServerTech) RPDU Sentry4
| Manufacturer: |
Server Technology Inc. (ServerTech) |
| Device Type: |
RPDU |
| Family: |
Sentry4 |
| Protocol: |
SNMP |
Models Tested:
| CW-16H2C452 |
| CW-16HEK454 |
| CWG-24V4K458A9 |
| CX-16H2C452 |
| STV-4102C/C |
Network Cards:
| Network Management Module |
| Firmware Versions: |
| 7.0k |
| 7.0p |
| 7.0t |
Additional Information:
Reference Documents:
| Document: |
Sentry3.mib |
| Version: |
201406251200Z |
| Sections: |
systemGroup (.1.3.6.1.4.1.1718.3.1.*)
towerTable (.1.3.6.1.4.1.1718.3.2.1.*)
infeedTable (.1.3.6.1.4.1.1718.3.2.2.*)
outletTable (.1.3.6.1.4.1.1718.3.2.3.*)
envMonTable (.1.3.6.1.4.1.1718.3.2.4.*)
tempHumidSensorTable (.1.3.6.1.4.1.1718.3.2.5.*)
contactClosureTable (.1.3.6.1.4.1.1718.3.2.6.*)
|
| URL: |
https://www.servertech.com/support/sentry-mib-oid-tree-downloads/
|
Server Technology Inc. (ServerTech) RPDU Sentry4
| Manufacturer: |
Server Technology Inc. (ServerTech) |
| Device Type: |
RPDU |
| Family: |
Sentry4 |
| Protocol: |
SNMP |
Models Tested:
| C2W36CE-DCMFAM00 |
| C2S36CE-YQME2M66/C |
| C2WG36CE-2CAF2M63 |
Network Cards:
| Smart PRO2 |
| Firmware Versions: |
| 8.0b |
| 8.0k |
| 8.0n |
Additional Information:
Reference Documents:
| Document: |
Sentry4.mib |
| Version: |
202007021900Z |
| Sections: |
st4Units (.1.3.6.1.4.1.1718.4.1.2.*)
st4InputCords (.1.3.6.1.4.1.1718.4.1.3.*)
st4Lines (.1.3.6.1.4.1.1718.4.1.4.*)
st4Phases (.1.3.6.1.4.1.1718.4.1.5.*)
st4OverCurrentProtectors (.1.3.6.1.4.1.1718.4.1.6.*)
st4Branches (.1.3.6.1.4.1.1718.4.1.7.*)
st4Outlets (.1.3.6.1.4.1.1718.4.1.8.*)
st4TemperatureSensors (.1.3.6.1.4.1.1718.4.1.9.*)
st4HumiditySensors (.1.3.6.1.4.1.1718.4.1.10.*)
st4WaterSensors (.1.3.6.1.4.1.1718.4.1.11.*)
st4ContactClosureSensors (.1.3.6.1.4.1.1718.4.1.12.*)
st4AnalogToDigitalConvSensors (.1.3.6.1.4.1.1718.4.1.13.*)
st4FanSensors (.1.3.6.1.4.1.1718.4.1.14.*)
|
| URL: |
https://www.servertech.com/support/sentry-mib-oid-tree-downloads/
|
Siemens AG Power Meter SENTRON PAC3200 Power Monitoring Device
| Manufacturer: |
Siemens AG |
| Device Type: |
Power Meter |
| Family: |
SENTRON PAC3200 Power Monitoring Device |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Siemens SENTRON, Power Monitoring Device SENTRON PAC3200, Manual |
| Version: |
Feb 2008, A5E01168664B-04 |
| Sections: |
Tables 3-6, 3-10, 3-11, 3-12, 3-13, 3-14, 3-15, 3-16, 3-17, 3-18, 3-19, 3-20, 3-21 (pgs.40-57) |
| URL: |
https://support.industry.siemens.com/cs/attachments/26504150/A5E01168664B-04_EN-US_122016_201612221316360495.pdf
|
Sinetica Unit Controller Hawk i2
| Manufacturer: |
Sinetica |
| Device Type: |
Unit Controller |
| Family: |
Hawk i2 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Socomec UPS Net Vision 6
| Manufacturer: |
Socomec |
| Device Type: |
UPS |
| Family: |
Net Vision 6 |
| Protocol: |
SNMP |
Models Tested:
| DELPHYS MP PARALLEL 80 kVA |
| ITYS 6 kVA |
| MASTERYS 3/3 SYSTEM 60 kVA |
| THREE/THREE UPS 160 kVA |
Network Cards:
| Net Vision 6 |
| Firmware Versions: |
| 6.01 |
| 6.21 |
| 6.32 |
Additional Information:
Reference Documents:
| Document: |
NetVision-nv620-win.mib |
| Version: |
6.20 |
| Sections: |
upsIdent (.1.3.6.1.4.1.4555.1.1.1.1.1.*)
upsBattery (.1.3.6.1.4.1.4555.1.1.1.2.1.*)
upsInput (.1.3.6.1.4.1.4555.1.1.1.1.3.*)
upsOutput (.1.3.6.1.4.1.4555.1.1.1.1.4.*)
upsBypass (.1.3.6.1.4.1.4555.1.1.1.1.5.*)
upsAlarm (.1.3.6.1.4.1.4555.1.1.1.1.6.*)
emdStatus (.1.3.6.1.4.1.4555.1.1.1.1.11.*)
|
| URL: |
|
Socomec Power Meter DIRIS Digiware M and D
| Manufacturer: |
Socomec |
| Device Type: |
Power Meter |
| Family: |
DIRIS Digiware M and D |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
| Firmware Versions: |
| 2.2.8.2 |
Additional Information:
Reference Documents:
Socomec UPS Net Vision 7
| Manufacturer: |
Socomec |
| Device Type: |
UPS |
| Family: |
Net Vision 7 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
NetVision-7_1_2.mib |
| Version: |
7.12 |
| Sections: |
upsIdent (.1.3.6.1.4.1.4555.1.1.7.1.1.*)
upsBattery (.1.3.6.1.4.1.4555.1.1.7.2.1.*)
upsInput (.1.3.6.1.4.1.4555.1.1.7.1.3.*)
upsOutput (.1.3.6.1.4.1.4555.1.1.7.1.4.*)
upsBypass (.1.3.6.1.4.1.4555.1.1.7.1.5.*)
upsAlarm (.1.3.6.1.4.1.4555.1.1.7.1.6.*)
|
| URL: |
https://www.socomec.com/net-vision-7-software_en.html
|
Socomec Inc. Power Meter Diris A10 Modular Power Metering and Monitoring Device
| Manufacturer: |
Socomec Inc. |
| Device Type: |
Power Meter |
| Family: |
Diris A10 Modular Power Metering and Monitoring Device |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Socomec Inc. Power Meter Diris A40/A41 Multifunction Meter
| Manufacturer: |
Socomec Inc. |
| Device Type: |
Power Meter |
| Family: |
Diris A40/A41 Multifunction Meter |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Socomec Inc. Power Meter Diris A60 Multifunction Meter
| Manufacturer: |
Socomec Inc. |
| Device Type: |
Power Meter |
| Family: |
Diris A60 Multifunction Meter |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Socomec Inc. Power Meter Diris A80 Multifunction Meter
| Manufacturer: |
Socomec Inc. |
| Device Type: |
Power Meter |
| Family: |
Diris A80 Multifunction Meter |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Socomec Inc. Power Meter Diris A20 Modular Power Metering and Monitoring Device
| Manufacturer: |
Socomec Inc. |
| Device Type: |
Power Meter |
| Family: |
Diris A20 Modular Power Metering and Monitoring Device |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
Stulz EMS WIB 8000
| Manufacturer: |
Stulz |
| Device Type: |
EMS |
| Family: |
WIB 8000 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| WIB 8000 |
| Firmware Versions: |
| 1.25 |
| 1.32 |
| 1.35 |
| 1.37 |
| 1.40 |
| 1.42 |
Additional Information:
Reference Documents:
| Document: |
StulzWIB8000_v152.mib |
| Version: |
v152 |
| Sections: |
infoValTemperatureTable:
unitAirTemperature (.1.3.6.1.4.1.29462.10.2.1.1.1.1.1.1.1.1170.*)
unitReturnAirTemperature (.1.3.6.1.4.1.29462.10.2.1.1.1.1.1.1.1.1192.*)
unitSupplyAirTemperature (.1.3.6.1.4.1.29462.10.2.1.1.1.1.1.1.1.1193.*)
unitOutsideAirTemperature (.1.3.6.1.4.1.29462.10.2.1.1.1.1.1.1.1.1196.*)
unitOutsideAirHumidity (.1.3.6.1.4.1.29462.10.2.1.1.1.1.1.1.1.1197.*)
infoValHumidityTable:
unitHumidity (.1.3.6.1.4.1.29462.10.2.1.1.1.1.2.1.1.1171.*)
unitReturnAirHumidity (.1.3.6.1.4.1.29462.10.2.1.1.1.1.2.1.1.1194.*)
unitSupplyAirHumidity (.1.3.6.1.4.1.29462.10.2.1.1.1.1.2.1.1.1195.*)
infoValPressureTable:
currentRaisedFloorPressure (.1.3.6.1.4.1.29462.10.2.1.1.1.1.3.1.1.1208.*)
infoValWaterTable:
waterInTemperatu1ChillersPrimary (.1.3.6.1.4.1.29462.10.2.1.1.1.2.1.1.1191.*)
waterInTemperatuhillersSecondary (.1.3.6.1.4.1.29462.10.2.1.1.1.2.1.1.1202.*)
waterOutTemperatChillersPrimary (.1.3.6.1.4.1.29462.10.2.1.1.1.2.1.1.1206.*)
waterOutTemperatillersSecondary (.1.3.6.1.4.1.29462.10.2.1.1.1.2.1.1.1207.*)
infoValRefrigerantTable:
unitSuctionPressure1 (.1.3.6.1.4.1.29462.10.2.1.1.1.3.1.1.2278.*)
unitSuctionPressure2 (.1.3.6.1.4.1.29462.10.2.1.1.1.3.1.1.2279.*)
runningHoursFliter (.1.3.6.1.4.1.29462.10.2.1.1.1.3.1.1.10291.*)
infoValAEcontrolTable:
operationMode (.1.3.6.1.4.1.29462.10.2.1.1.1.4.1.1.10315.*)
infoStatRuntimesTable:
unitRuntimeUnit (.1.3.6.1.4.1.29462.10.2.1.1.4.4.3.1.1164.*)
|
| URL: |
Not Available
|
Stulz Crac SplitAir3
| Manufacturer: |
Stulz |
| Device Type: |
Crac |
| Family: |
SplitAir3 |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
STULTZ Data Point List Secblue.pdf |
| Version: |
5 |
| Sections: |
Not Available
|
| URL: |
Not Available
|
Toshiba International Corp UPS RemotEye 4-based G9000 UPS
| Manufacturer: |
Toshiba International Corp |
| Device Type: |
UPS |
| Family: |
RemotEye 4-based G9000 UPS |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Toshiba RemotEye 4 |
| Firmware Versions: |
| RK8FD0_T4.ldRFGXA0.hex JEA1490A |
Additional Information:
| for devices with upsIdentTypeform (1.3.6.1.4.1.186.1.19.2.5.8.1.2) starting with "T901H","T90N3P","T90S3S" |
Reference Documents:
Toshiba International Corp UPS RemotEye II-based
| Manufacturer: |
Toshiba International Corp |
| Device Type: |
UPS |
| Family: |
RemotEye II-based |
| Protocol: |
SNMP |
Models Tested:
| 1000-series |
| G8000MM |
| G9000 |
Network Cards:
| Toshiba RemotEye II |
| Firmware Versions: |
| Main v1.0, Interface v1.0 |
| RK8FD0_T4.ldRFGXA0.hex JEA1490A |
Additional Information:
Reference Documents:
Toshiba International Corp UPS RemotEye 4-based 1600XP UPS
| Manufacturer: |
Toshiba International Corp |
| Device Type: |
UPS |
| Family: |
RemotEye 4-based 1600XP UPS |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Toshiba RemotEye 4 |
| Firmware Versions: |
| main firmware version: UH3MSV01050, boot sector version: UH3MBS01000, boot loader version: UH3MBL01000, EEPROM version: UH3MEE01050 |
Additional Information:
| for devices with upsIdentTypeform (1.3.6.1.4.1.186.1.19.2.5.2.1.2) starting with "UH3G2L","H3BE1E","H3BG2L" |
Reference Documents:
Toshiba International Corp UPS RemotEye III-based
| Manufacturer: |
Toshiba International Corp |
| Device Type: |
UPS |
| Family: |
RemotEye III-based |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Toshiba RemotEye III |
| Firmware Versions: |
| UH3MSV01050 |
Additional Information:
Reference Documents:
TrendPoint BCM EnerSure
| Manufacturer: |
TrendPoint |
| Device Type: |
BCM |
| Family: |
EnerSure |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Network Management Module |
| Firmware Versions: |
| 3800 |
| 4900 |
Additional Information:
Reference Documents:
| Document: |
TRENDPOINT-ENERSURE-MIB |
| Version: |
201010260000Z |
| Sections: |
tpEsStack (.1.3.6.1.4.1.10381.1.3.1.1)
tpEsCircuits (.1.3.6.1.4.1.10381.1.3.1.3)
|
| URL: |
Not Available
|
Tripp Lite RPDU SNMPWEBCARD
| Manufacturer: |
Tripp Lite |
| Device Type: |
RPDU |
| Family: |
SNMPWEBCARD |
| Protocol: |
SNMP |
Models Tested:
| PDU3VSR6L1530 |
| PDUMH20AT |
| PDUMH20ATNET |
| PDUMV30HVNET |
Network Cards:
| SNMPWEBCARD |
| Firmware Versions: |
| 6926680B |
| 6929220B |
| 6929890B |
Additional Information:
Reference Documents:
Tripp Lite RPDU WEBCARDLX
| Manufacturer: |
Tripp Lite |
| Device Type: |
RPDU |
| Family: |
WEBCARDLX |
| Protocol: |
SNMP |
Models Tested:
| PDUMH15NET |
| PDUMVR30HVNETLX |
Network Cards:
| WEBCARDLX |
| Firmware Versions: |
| 6926600B |
| 693038B |
Additional Information:
Reference Documents:
| Document: |
TRIPPLITE-PRODUCTS.mib |
| Version: |
202012160000Z |
| Sections: |
tlpPduIdent (.1.3.6.1.4.1.850.1.1.3.2.1.*)
tlpPduDevice (.1.3.6.1.4.1.850.1.1.3.2.2.*)
tlpPduInput (.1.3.6.1.4.1.850.1.1.3.2.3.1.*)
tlpPduOutput (.1.3.6.1.4.1.850.1.1.3.2.3.2.*)
tlpPduOutlet (.1.3.6.1.4.1.850.1.1.3.2.3.3.*)
tlpPduCircuit (.1.3.6.1.4.1.850.1.1.3.2.3.4.*)
tlpPduBreaker (.1.3.6.1.4.1.850.1.1.3.2.3.5.*)
tlpEnvTemperatureTable (.1.3.6.1.4.1.850.1.1.3.3.3.1.*)
tlpEnvHumidityTable (.1.3.6.1.4.1.850.1.1.3.3.3.2.*)
tlpEnvInputContactTable (.1.3.6.1.4.1.850.1.1.3.3.3.3.*)
tlpEnvOutputContactTable (.1.3.6.1.4.1.850.1.1.3.3.3.4.*)
|
| URL: |
https://www.tripplite.com/products/management-firmware-matrix
|
Tripp Lite UPS SNMPWEBCARD
| Manufacturer: |
Tripp Lite |
| Device Type: |
UPS |
| Family: |
SNMPWEBCARD |
| Protocol: |
SNMP |
Models Tested:
| SMART750RM1U |
| SMART1000RM1U |
| SU1500RTXL2Ua |
| SU10000RT3UPM |
Network Cards:
| SNMPWEBCARD |
| Firmware Versions: |
| 08 |
| 19 |
| 1218 (Rev A) |
| 2264 (Rev A) |
Additional Information:
Reference Documents:
Tripp Lite ATS WEBCARDLX
| Manufacturer: |
Tripp Lite |
| Device Type: |
ATS |
| Family: |
WEBCARDLX |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| WEBCARDLX |
| Firmware Versions: |
| 6924150A |
Additional Information:
Reference Documents:
| Document: |
TRIPPLITE-PRODUCTS.mib |
| Version: |
202012160000Z |
| Sections: |
tlpAtsIdent (.1.3.6.1.4.1.850.1.1.3.4.1.*)
tlpAtsDevice (.1.3.6.1.4.1.850.1.1.3.4.2.*)
tlpAtsInput (.1.3.6.1.4.1.850.1.1.3.4.3.1.*)
tlpAtsOutput (.1.3.6.1.4.1.850.1.1.3.4.3.2.*)
tlpAtsOutlet (.1.3.6.1.4.1.850.1.1.3.4.3.3.*)
|
| URL: |
https://www.tripplite.com/products/management-firmware-matrix
|
Various UPS RFC1628-compliant UPS
| Manufacturer: |
Various |
| Device Type: |
UPS |
| Family: |
RFC1628-compliant UPS |
| Protocol: |
SNMP |
Models Tested:
| Chloride 80Net |
| CPS OL2000ERTXL2U |
| Delta GES602R2120B0 |
| HP RT3000 G2 UPS |
| TrippLite SU1500RTXLCD2U |
| TrippLite SU2200RTXLCD2U |
Network Cards:
Additional Information:
|
Devices adhering to the standard set forth in the IETF's document RFC 1628,
which defines a standard set of measurement, setting, and alarm data points
for Uninterruptible Power Supply (UPS) systems.
|
Reference Documents:
Vertiv CRAC EEV
| Manufacturer: |
Vertiv |
| Device Type: |
CRAC |
| Family: |
EEV |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 6.5.0.0 |
Additional Information:
Reference Documents:
| Document: |
LIEBERT-GP-ENVIRONMENTAL-MIB |
| Version: |
v.18, Tue Jul 28 21:49:40 EDT 2020 |
| Sections: |
1.3.6.1.4.1.476.1.42.3.4.* |
| URL: |
Not Available
|
Vertiv / Emerson Network Power UPS NXC
| Manufacturer: |
Vertiv / Emerson Network Power |
| Device Type: |
UPS |
| Family: |
NXC |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
nxc3040k.mib |
| Version: |
200911231030Z |
| Sections: |
.1.3.6.1.4.1.13400.2.43.* |
| URL: |
Not Available
|
Vertiv / Emerson Network Power UPS NXR
| Manufacturer: |
Vertiv / Emerson Network Power |
| Device Type: |
UPS |
| Family: |
NXR |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
nxr.mib |
| Version: |
200902011512Z |
| Sections: |
.1.3.6.1.4.1.13400.2.19.* |
| URL: |
Not Available
|
Vertiv / Emerson Network Power UPS GXT4
| Manufacturer: |
Vertiv / Emerson Network Power |
| Device Type: |
UPS |
| Family: |
GXT4 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
ENP UPS GXT4G.mib |
| Version: |
revision 200, 201309020955Z |
| Sections: |
.1.3.6.1.4.1.13400.2.439.* |
| URL: |
Not Available
|
Vertiv / Emerson Network Power UPS GXT3
| Manufacturer: |
Vertiv / Emerson Network Power |
| Device Type: |
UPS |
| Family: |
GXT3 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
GXT3G.mib |
| Version: |
200902011512Z |
| Sections: |
.1.3.6.1.4.1.13400.2.71.* |
| URL: |
Not Available
|
Vertiv / Geist Environmental Monitor Geist Blackbird series
| Manufacturer: |
Vertiv / Geist |
| Device Type: |
Environmental Monitor |
| Family: |
Geist Blackbird series |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
GEIST-V4-MIB |
| Version: |
201209110000Z |
| Sections: |
1.3.6.1.4.1.21239.5.1.* |
| URL: |
Not Available
|
Vertiv / Liebert CRAC CRV
| Manufacturer: |
Vertiv / Liebert |
| Device Type: |
CRAC |
| Family: |
CRV |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Vertiv CRV 030 inrow cooler (rdu sic G2) |
| Version: |
Not Available
|
| Sections: |
rows 6-79,96-203, function 3 registers 1-74, function 1 registers 1-108 |
| URL: |
Not Available
|
Vertiv / Liebert Branch Circuit Monitor LDMF Controller
| Manufacturer: |
Vertiv / Liebert |
| Device Type: |
Branch Circuit Monitor |
| Family: |
LDMF Controller |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Liebert(R) IntelliSlot(TM) Modbus and BACnet Protocols, Reference Guide |
| Version: |
Not Available
|
| Sections: |
Tables 3.46-3.47 (pgs.374-386) |
| URL: |
Not Available
|
Vertiv / Liebert CRAC Liebert iCOM v4 Controller
| Manufacturer: |
Vertiv / Liebert |
| Device Type: |
CRAC |
| Family: |
Liebert iCOM v4 Controller |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
Additional Information:
Reference Documents:
| Document: |
Liebert(R) IntelliSlot(TM) Modbus and BACnet Protocols, Reference Guide |
| Version: |
Not Available
|
| Sections: |
Tables 3.1-3.2 (pgs.19-71) |
| URL: |
Not Available
|
Vertiv / Liebert Corporation Rack PDU MPH/MPX (RPC2)
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
Rack PDU |
| Family: |
MPH/MPX (RPC2) |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| RPC2 |
| Firmware Versions: |
| 12.0.0.5 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation Chiller iCOM SC, type HPC
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
Chiller |
| Family: |
iCOM SC, type HPC |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Web Card |
| Firmware Versions: |
| 5.280.3 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation Rack PDU MPH
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
Rack PDU |
| Family: |
MPH |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Rack PDU Card |
| Firmware Versions: |
| 4.840.0 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation CRAC iCOM PA, type DSE
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
CRAC |
| Family: |
iCOM PA, type DSE |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 3.0.0.0 |
| 4.2.0.0 |
Additional Information:
Reference Documents:
| Document: |
LIEBERT-GP-ENVIRONMENTAL-MIB |
| Version: |
v.18, Tue Jul 28 21:49:40 EDT 2020 |
| Sections: |
1.3.6.1.4.1.476.1.42.3.4.* |
| URL: |
Not Available
|
Vertiv / Liebert Corporation Rack PDU MPX
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
Rack PDU |
| Family: |
MPX |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| Rack PDU Card |
| Firmware Versions: |
| 4.940.0 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation CRAC iCOM PA, type HPM
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
CRAC |
| Family: |
iCOM PA, type HPM |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 5.0.0.0 |
Additional Information:
Reference Documents:
| Document: |
LIEBERT-GP-ENVIRONMENTAL-MIB |
| Version: |
v.18, Tue Jul 28 21:49:40 EDT 2020 |
| Sections: |
1.3.6.1.4.1.476.1.42.3.4.* |
| URL: |
Not Available
|
Vertiv / Liebert Corporation CRAC CEMS100/LECS15
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
CRAC |
| Family: |
CEMS100/LECS15 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Web/485 Card |
| Firmware Versions: |
| 5.2A0.7 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation Power Meter Extended Power Management Panel (EPMP)
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
Power Meter |
| Family: |
Extended Power Management Panel (EPMP) |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Web/485 Card |
| Firmware Versions: |
| 3.120.6 |
| 3.120.7 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation CRAC CRV Row-based Environmental Control System
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
CRAC |
| Family: |
CRV Row-based Environmental Control System |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Web/485 Card |
| Firmware Versions: |
| 5.280.2 |
| OpenComms Web Card |
| Firmware Versions: |
| 5.010.10 |
Additional Information:
Reference Documents:
| Document: |
LIEBERT-GP-ENVIRONMENTAL-MIB |
| Version: |
v.18, Tue Jul 28 21:49:40 EDT 2020 |
| Sections: |
1.3.6.1.4.1.476.1.42.3.4.* |
| URL: |
Not Available
|
Vertiv / Liebert Corporation CRAC iCOM PA, type PEX
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
CRAC |
| Family: |
iCOM PA, type PEX |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 6.0.0.0 |
Additional Information:
Reference Documents:
| Document: |
LIEBERT-GP-ENVIRONMENTAL-MIB |
| Version: |
v.18, Tue Jul 28 21:49:40 EDT 2020 |
| Sections: |
1.3.6.1.4.1.476.1.42.3.4.* |
| URL: |
Not Available
|
Vertiv / Liebert Corporation CRAC iCOM
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
CRAC |
| Family: |
iCOM |
| Protocol: |
SNMP |
Models Tested:
| Liebert DELUXE |
| Liebert HIMOD |
| Liebert PEX |
| ICOM Environmental Control |
| Liebert DS |
Network Cards:
| IntelliSlot Web Card |
| Firmware Versions: |
| 3.210.0 |
| 5.050.0 |
| OpenComms Web Card |
| Firmware Versions: |
| 3.010.0 |
Additional Information:
Reference Documents:
| Document: |
LIEBERT-GP-ENVIRONMENTAL-MIB |
| Version: |
v.18, Tue Jul 28 21:49:40 EDT 2020 |
| Sections: |
1.3.6.1.4.1.476.1.42.3.4.* |
| URL: |
Not Available
|
Vertiv / Liebert Corporation CRAC iCOM PA, type DS
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
CRAC |
| Family: |
iCOM PA, type DS |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Web Card |
| Firmware Versions: |
| 5.280.2 |
Additional Information:
Reference Documents:
| Document: |
LIEBERT-GP-ENVIRONMENTAL-MIB |
| Version: |
v.18, Tue Jul 28 21:49:40 EDT 2020 |
| Sections: |
1.3.6.1.4.1.476.1.42.3.4.* |
| URL: |
Not Available
|
Vertiv / Liebert Corporation CRAC Advanced Microprocessor Cooling
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
CRAC |
| Family: |
Advanced Microprocessor Cooling |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Web/485 Card |
| Firmware Versions: |
| 5.2A0.2 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation CRAC Deluxe System 3
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
CRAC |
| Family: |
Deluxe System 3 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 4.3.0.0 |
Additional Information:
Reference Documents:
| Document: |
LIEBERT-GP-ENVIRONMENTAL-MIB |
| Version: |
v.18, Tue Jul 28 21:49:40 EDT 2020 |
| Sections: |
1.3.6.1.4.1.476.1.42.3.4.* |
| URL: |
Not Available
|
Vertiv / Liebert Corporation Transfer Switch Static Transfer Switch 2
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
Transfer Switch |
| Family: |
Static Transfer Switch 2 |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Web/485 Card |
| Firmware Versions: |
| 3.120.7 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation CRAC MiniMate 2
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
CRAC |
| Family: |
MiniMate 2 |
| Protocol: |
SNMP |
Models Tested:
| Mini-Mate2 Control |
| Mini-Mate2 8-Ton Control |
Network Cards:
| IntelliSlot Web/485 Card |
| Firmware Versions: |
| 3.120.5 |
| 3.120.7 |
| 5.2A0.1 |
| 5.2A0.2 |
| IntelliSlot Unity Card |
| Firmware Versions: |
| 8.0.0.0 |
Additional Information:
Reference Documents:
Vertiv / Liebert Corporation CRAC iCOM PA, type PEXS
| Manufacturer: |
Vertiv / Liebert Corporation |
| Device Type: |
CRAC |
| Family: |
iCOM PA, type PEXS |
| Protocol: |
SNMP |
Models Tested:
Network Cards:
| IntelliSlot Unity Card |
| Firmware Versions: |
| 6.6.0.0 |
| 7.8.0.0-4.2.1 |
Additional Information:
Reference Documents:
Woodward Inc. Generator easYgen 3000XT Series
| Manufacturer: |
Woodward Inc. |
| Device Type: |
Generator |
| Family: |
easYgen 3000XT Series |
| Protocol: |
MODBUS |
Models Tested:
Network Cards:
| Modbus RTU over RS485 |
| Modbus TCP over Ethernet |
Additional Information:
Reference Documents:
| Document: |
Woodward easyGen-3000XT Series Manual |
| Version: |
Software Version 2.10-2, Document ID B37574, Revision L - Build 50616 |
| Sections: |
Section 9.2.7, "Protocol 5016 (Basic Visualization)" (pgs.977-997,1007-1016) |
| URL: |
Not Available
|